Failure to Load the Host Version in A1 Loading Mode When a PC Is Directly Connected to the SoftCo

Publication Date:  2015-07-24 Views:  156 Downloads:  0
Issue Description
When a PC is directly connected to the SoftCo, the host version fails to be loaded in A1 loading mode.
Handling Process
Step 1 Ensure that the PC network adapter is a gigabit network adapter and set the network port mode of the PC network adapter to that of the SoftCo, specifically, 100 M full-duplex mode.





Step 2 Ensure that the IP address in the switch.dat file is the IP address of the SoftCo.

Step 3 If the fault persists, contact Huawei technical support engineers.

----End
Root Cause
1.  The host IP address of the SoftCo is different from the IP address of the PC.

2.  The network port mode of the PC network adapter is different from that of the SoftCo.

3.  The IP address in the Switch.dat file is incorrect.

END