S5700因PC终端接入端口拥塞导致网络同传速度慢

发布时间:  2015-05-23 浏览次数:  1158 下载次数:  0
问题描述

联想主机使用网络同传功能,如服务器与主机直连同传操作系统,传输时间很短(1小时以内),但接入华为S5700交换机时网络同传速度很慢,耗时达十多个小时。

 

处理过程

1、检查该设备版本是否开启端口或VLAN广播抑制功能,S5700 V2R1版本未默认不开启广播抑制功能。

2、关闭设备STP功能测试,问题仍未解决。

3、检查设备信息,使用命令display interface brief查询设备端口流量,发现设备端口流量异常。

===========================================================
  ===============display interface brief===============
===========================================================
PHY: Physical
*down: administratively down
(l): loopback
(s): spoofing
(b): BFD down
(e): ETHOAM down
(dl): DLDP down
(d): Dampening Suppressed
InUti/OutUti: input utility/output utility
Interface                   PHY   Protocol InUti OutUti   inErrors  outErrors
GigabitEthernet0/0/1        up    up          0%    73%          0          0
GigabitEthernet0/0/2        up    up         73%  0.98%          0          0  //接入同传服务器端口,其余端口接入PC终端
GigabitEthernet0/0/3        up    up       0.76%   100%          0          0
GigabitEthernet0/0/4        up    up          0%    73%          0          0
GigabitEthernet0/0/5        up    up       0.76%   100%          0          0
GigabitEthernet0/0/6        up    up          0%    73%          0          0
GigabitEthernet0/0/7        up    up          0%    73%          0          0
GigabitEthernet0/0/8        up    up          0%    73%          0          0
GigabitEthernet0/0/9        up    up          0%    73%          0          0
GigabitEthernet0/0/10       up    up          0%    73%          0          0
GigabitEthernet0/0/11       up    up          0%    73%          0          0
GigabitEthernet0/0/12       up    up          0%    73%          0          0
GigabitEthernet0/0/13       up    up          0%    73%          0          0
GigabitEthernet0/0/14       up    up          0%    73%          0          0
GigabitEthernet0/0/15       up    up       2.52%   100%          0          0
GigabitEthernet0/0/16       up    up          0%    73%          0          0
GigabitEthernet0/0/17       up    up          0%    73%          0          0
GigabitEthernet0/0/18       up    up          0%    73%          0          0
GigabitEthernet0/0/19       up    up          0%    73%          0          0
GigabitEthernet0/0/20       up    up          0%    73%          0          0
GigabitEthernet0/0/21       up    up          0%    73%          0          0
GigabitEthernet0/0/22       up    up          0%    73%          0          0
GigabitEthernet0/0/23       up    up          0%    73%          0          0
GigabitEthernet0/0/24       up    up       0.57%    73%          0          0

 

使用命令display interface GigabitEthernet0/0/2 查询服务器接入端口:

GigabitEthernet0/0/2 current state : UP
Line protocol current state : UP
Description:
Switch Port, PVID :   80, TPID : 8100(Hex), The Maximum Frame Length is 10224
IP Sending Frames' Format is PKTFMT_ETHNT_2, Hardware address is dcd2-fcf8-00a0
Current system time: 2008-10-01 01:27:52-05:13
Port Mode: COMMON COPPER
Speed : 1000,  Loopback: NONE                         //表示服务器接入端口工作在1000M速率
Duplex: FULL,  Negotiation: ENABLE
Mdi   : AUTO
......

    Input bandwidth utilization threshold : 100.00%
    Output bandwidth utilization threshold: 100.00%
    Input bandwidth utilization  :   73%
    Output bandwidth utilization : 1.00%

 

使用命令display interface GigabitEthernet0/0/3 查询异常PC终端接入端口:

GigabitEthernet0/0/3 current state : UP
Line protocol current state : UP
Description:
Switch Port, PVID :   80, TPID : 8100(Hex), The Maximum Frame Length is 1600
IP Sending Frames' Format is PKTFMT_ETHNT_2, Hardware address is dcd2-fcf8-00a0
Current system time: 2008-10-01 01:27:54-05:13
Port Mode: COMMON COPPER
Speed :  100,  Loopback: NONE                       //表示该PC终端接入端口工作在100M速率
Duplex: FULL,  Negotiation: ENABLE  
Mdi   : AUTO
......
    Input bandwidth utilization threshold : 100.00%
    Output bandwidth utilization threshold: 100.00%
    Input bandwidth utilization  : 0.80%
    Output bandwidth utilization :  100%            //该端口发送速率一直为100%

 

同传服务器端口业务进入流量速率在73%,大部分终端接入端口业务发送速率也在73%,但部分接入终端端口发送速率达到100%。

经排查,同传服务器及大部分终端接入端口工作速率在1000M全双工模式,而所有接入终端端口发送速率为100%端口均工作在100M全双工模式。


4、强制同传服务器连接交换机端口工作在100M全双工模式,网络同传速度正常。

[Quidway]interface GigabitEthernet 0/0/2
[Quidway-GigabitEthernet0/0/2]undo negotiation auto
[Quidway-GigabitEthernet0/0/2]speed 100

 

根因

由于交换机的流控机制。当PC终端与同传服务器进行网络同传业务时,由于服务器发送业务数据速率超过了PC终端端口接收速率,它会向服务器发出PAUSE帧,以延缓服务器向PC终端的数据传输,导致网络同传速率变慢。

交换机的流量控制机制:流量控制用于防止在端口阻塞的情况下丢帧,这种方法是当发送或接收缓冲区开始溢出时通过将阻塞信号发送回源地址实现的。流量控制可以有效的防止由于网络中瞬间的大量数据对网络带来的冲击,保证用户网络高效而稳定的运行。

解决方案

1、设置同传服务器数据发送速率。

2、确保同传服务器接入端口工作速率与PC终端接入端口速率一致,或不超过PC终端接入端口速率。

END