S6700交换机由于光模块原因导致无法配置业务口堆叠

发布时间:  2015-06-16 浏览次数:  360 下载次数:  0
问题描述

1、版本信息:

[LANSW-03]dis version
Huawei Versatile Routing Platform Software
VRP (R) software, Version 5.130 (S6700 V200R003C00SPC300)
Copyright (C) 2000-2013 HUAWEI TECH CO., LTD
Quidway S6700-48-EI Routing Switch uptime is 0 week, 0 day, 1 hour, 20 minutes

2、组网概述:

对两台S6700-48-EI采用其中的XG0/0/44和XG0/0/45进行业务口堆叠

 

告警信息

1、告警信息:

[LANSW-03-stack-port0/1]port int xg0/0/45 enable
Warning: Enabling stack port cause configuration loss on the interface, continue?[Y/N]:y
Error: Configuration failed. Please check optical module(s).  

处理过程

1、因为S6700的接口工作在GE模式时不支持堆叠,所以检查XG0/0/44和XG0/0/45光模块信息,符合要求

[LANSW-03]dis transceiver interface XGigabitEthernet 0/0/45 verbose
XGigabitEthernet0/0/45 transceiver information:
-------------------------------------------------------------
Common information:
Transceiver Type               :10GBBASE_SR_SFP
Connector Type                 :LC
Wavelength(nm)                 :850
Transfer Distance(m)           :33(OM1),82(OM2),300(OM3),400(OM4)
Digital Diagnostic Monitoring  :YES
Vendor Name                    :HUAWEI
Vendor Part Number             :02318169
Ordering Name                  :
-------------------------------------------------------------
Manufacture information:
Manu. Serial Number            :CF19HP0X9      
Manufacturing Date             :2015-05-14
Vendor Name                    :HUAWEI
-------------------------------------------------------------
Diagnostic information:
Temperature(°C)              :31.96
Temp High Threshold(°C)      :80.00
Temp Low  Threshold(°C)      :-10.00
Voltage(V)                    :3.29
Volt High Threshold(V)        :3.63
Volt Low  Threshold(V)        :2.97
Bias Current(mA)              :5.07
Bias High Threshold(mA)       :10.00
Bias Low  Threshold(mA)       :2.60
RX Power(dBM)                 :-2.78
RX Power High Threshold(dBM)  :0.99
RX Power Low  Threshold(dBM)  :-11.89
TX Power(dBM)                 :-2.22
TX Power High Threshold(dBM)  :0.99
TX Power Low  Threshold(dBM)  :-9.29
-------------------------------------------------------------

2、S6700要求端口号从小到大连续的每四个10G端口类型需要一致(都是业务口或者都是堆叠口),检查发现XG0/0/44-XG0/0/47没有被配置为业务口。

3、S6700要求端口号从小到大连续的每四个10G端口光模块类型需要一致,检查发现在空闲的XG0/0/46口上插入了一个1000M电口光模块,将电模块拔出后,再次配置XG0/0/45配置能够正常下发,堆叠成功。

根因

1、故障根因:

S6700要求端口号从小到大连续的每四个10G端口光模块类型不一致。

 

解决方案
将端口号从小到大连续的每四个10G端口光模块类型确保一致,如果空闲端口可以不插光模块。
建议与总结

S6700业务口堆叠要求:

1、端口不能为GE模式

2、端口号从小到大连续的每四个10G端口类型需要一致(都是业务口或者都是堆叠口。
3、端口号从小到大连续的每四个10G端口光模块类型需要一致。

END