TP3206 right TV display black screen automatically when join the conference

Publication Date:  2015-06-22 Views:  149 Downloads:  0
Issue Description
Discussed with customer,when only TP3206, RP200 and TE30 joined the conference. TP3206 left screen display RP200 local image, middle screen display TE30 local image automatically, no more other site to be displayed by TP3206 right screen, so by default it display black screen.custoemr hope that if not enough site join the conference, the right screen should display local image.
Handling Process

This is the default policy for MCU9630 in that scenario, in order to meet customer requirement, we can try to do the command on MCU:

system-view conf-policy enable-mp-see-self 1
save

If other 3 or above 3 sites join the meeting, the TP3206 all three screen should automatically display the other sites local image. if not enough site there, we can use command on MCU to make the right screen display local image

Root Cause

This is the default policy for MCU9630 in that scenario.

Solution

In order to meet customer requirement, we can try to do the command on MCU:

system-view conf-policy enable-mp-see-self 1
save

END