An IPC Is Pinged, but the Ping Fails Immediately

Publication Date:  2015-06-27 Views:  232 Downloads:  0
Issue Description
Applicable Models:
This fault may occur on all IPC models.


After an IPC is powered on, it can be pinged, but the ping fails immediately.
Handling Process
Step 1 Ensure that the IPC works in stable voltage.

Step 2 Capture data packets sent by the IPC and analyze the captured data packets.
  • If the IPC continuously sends broadcast packets to, upgrade the IPC to the latest version.
There might be network storms when the IPC connects to the optical network unit (ONU) of some models. If this occurs, upgrade the IPC to the latest version.
  • If the IPC sends packets normally, go to Step 3.
Step 3 Reset the IPC and ping the IPC again after powering it on.

Step 4 Check whether the fault is rectified.
  • If yes, no further operation is required.
  • If no, contact your service provider for assistance.
Root Cause
The possible causes are as follows:
  • The IPC voltage is unstable.
  • There is a network storm.