ES3000驱动安装后查询设备报错

发布时间:  2015-09-29 浏览次数:  762 下载次数:  0
问题描述

E3000, vMware5.5,安装驱动提示成功,查询设备时提示"driver module is not loaded"。

安装完成提示信息:

~ # esxcli software vib install -v /tmp/hio-2.0.0.42-1OEM.550.0.0.1331820.vib --no-sig-check --maintenance-mode Installation Result

   Message: The update completed successfully, but the system needs to be rebooted for the changes to be effective.

   Reboot Required: true

   VIBs Installed: HUAWEI_bootbank_hio_2.0.0.42-1OEM.550.0.0.1331820

   VIBs Removed:

   VIBs Skipped:

查询驱动安装状态提示信息:

~ # hio_info -d /dev/chioa

Error: driver module is not loaded

解决方案

1.确认硬件版本及物理上是否安装正确:

物理安装是正确的,硬件有ES3000/ES3000 V2两种,客户只知道是ES3000,通过查询BOQ确认客户现场是ES3000 V2

2.驱动包是否安装正确:

esxcli software vib install -v /tmp/hio-2.0.0.42-1OEM.550.0.0.1331820.vib (ES3000的驱动)

对照驱动ES3000 V2驱动包,驱动包hio-2.1.0.17-1OEM.550.0.0.1331820.vib

重新安装hio-2.1.0.17-1OEM.550.0.0.1331820.vib包后正常。

END