Anti_Ddos 8030 SPUA01单板无法注册

发布时间:  2015-12-07 浏览次数:  212 下载次数:  0
问题描述
两块SPUA01分别插在1和2号槽位,都无法注册有异常信息弹出来
告警信息

<AntiDDoS>dis dev
14:57:48  2015/11/04
AntiDDoS8030's Device status:
Slot #    Type       Online    Register      Status      Primary   
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
1         LPU/SPU    Present   Unregistered  Abnormal    NA        
2         LPU/SPU    Present   Unregistered  Abnormal    NA
        
3         LPU        Present   Registered    Normal      NA        
4         MPU        Present   NA            Normal      Master    
5         MPU        Present   Registered    Normal      Slave     
6         CLK        Present   Registered    Normal      Master

Nov  4 2015 14:44:23 AntiDDoS %%01SRM/3/LPURESET(l)[5]:LPU1 reset, the reason is board isn't registered over 20 mins.
Nov  4 2015 14:41:36 AntiDDoS %%01SRM/3/LPURESET(l)[6]:LPU2 reset, the reason is board isn't registered over 20 mins.


处理过程

1.Ddos 8030设备的业务板需要上传并激活licens才可以正常使用;

2.Ddos 8030的业务板只有配置为检测板或者清洗板之后才可以正常注册;


解决方案
加载licens并配置为检测板或者清洗板之后正常注册
建议与总结


指定检测或清洗业务板缺省情况下,业务板类型为防火墙业务板,不具有检测或清洗功能,用户需要指定某槽位业务板为检测业务板或清洗业务板。

如果业务板指定为检测业务板,则该业务板专门用于处理检测模块业务,从检测口到达的流量直接上送检测业务板进行处理;如果业务板指定为清洗业务板,则该业务板专门用于处理清洗模块业务,从清洗口到达的流量直接上送清洗业务板进行处理。

在用户视图下执行命令system-view,进入系统视图。

执行命令firewall ddos { detect-spu | clean-spu } slot slot-id,指定槽位业务板为检测业务板或清洗业务板。 当前槽位的业务板已经正常在位,此时配置此命令指定某槽位业务板作为检测或清洗业务板,为使功能生效,需执行命令reset slot slot-id,重新启动该业务板。

执行命令display ddos slot,查看业务板配置。

END