S系列POE交换机如何判断DIMM条故障

发布时间:  2015-11-13 浏览次数:  217 下载次数:  0
问题描述
S交换机的POE出现DIMM条松动或者异常导致的交换机异常供电,下面是一个测试方法确定DIMM条工作是否正常,从而判断出交换机供电异常的原因。
处理过程

1,设备重启进入BOOTROM界面。

Press Ctrl+B to enter BOOTROM menu ... 2
password:


          BOOTROM  MENU

    1. Boot with default mode
    2. Enter serial submenu
    3. Enter startup submenu
    4. Enter ethernet submenu
    5. Enter filesystem submenu
    6. Modify BOOTROM password
    7. Clear password for console user
    8. Reboot

Enter your choice(1-8):

2.在BOOTROM界面按住CTRL+E进入 BOOT-UP DIAG 菜单 在该界面选择:8


                     BOOT-UP DIAG MENU

   1. Sdram Test                 2. Flash Test
   3. Epld Test                  4. Temperature Test
   5. Reserved                   6. Show system information
   7. Aging Test                 8. E-Label Barcode and MAC Test
   9. Poe Test                  10. Startup File Test
  11. Reserved                  12. Return MainMenu
Enter your choice(1-12): 8

3.进入该子界面选择1

                   E-LABEL and MAC TEST SUBMENU

   1. Read E-LABEL test            2. Load E-LABEL test
   3. Set MAC address              4. Read MAC address
   5. Set Barcode and MAC          6. Read Barcode and MAC
   7. Set SubCard PcbVer Info      8. Read SubCard PcbVer Info
   9. Set SubCard barcode         10. Read SubCard barcode
  11. Return to BUDMENT        
Enter your choice(1-11): 1


4,在这个界面选择7和8测试DIMM条,S交换机POE供电一般有2个DIMM条
E-Label Display Test Start ......
Please select Display TargetBoard:
   1. MainCard       2. ForeCard
   3. HindCard       4. FansCard
   5. PowerCard I    6. PowerCard II
   7. DimmCard I     8. DimmCard II
Enter your choice(1-8): 7
Read E-Label Data From Slot 6 Board ...... Success

正常通过测试DIMM条测试结果。




E-Label Display Test Start ......
Please select Display TargetBoard:
   1. MainCard       2. ForeCard
   3. HindCard       4. FansCard
   5. PowerCard I    6. PowerCard II
   7. DimmCard I     8. DimmCard II
Enter your choice(1-8): 8
Read E-Label Data From Slot 7 Board ......
[Drv_SubCard_ReadE2promInfo()]: Don't support the EEPROM! [SLOT]7
Read SubCard[7] E2PROM ERROR.Fail

有异常的DIMM条测试结果
     

建议与总结
通过该测试方法,可以定位到POE交换机DIMM条故障引起了交换机的供电异常。