SNS2124与HP光纤交换机级联报错

发布时间:  2015-11-20 浏览次数:  643 下载次数:  0
问题描述

SNS2124与HP光纤交换机级联后,

在SNS2124的级联口报:
LE E-Port  segmented,10:00:00:05:1e:f5:7a:ac (incompatible)
在HP光纤交换机级联口报:
E-Port  segmented,(Op Mode incompat)
且有如下报错:
brocade_hp_san:admin> 2015/10/30-08:32:17, [FABR-1001], 1861, FID 128, WARNING, brocade_hp_san, port 23, incompatible flow control parameters (2).
2015/10/30-08:32:17, [FABR-1001], 1862, FID 128, WARNING, brocade_hp_san, port 23, incompatible flow control parameters (2).

处理过程

brocade交换机能支持在ISL上的两种流控方法:
Virtual Channel (VC_RDY)
Receiver Ready (R_RDY)

可以用portcfgshow查看ISL流控的配置信息

SNS2124:
Ports of Slot 0       23
-------------------------
Speed                 AN
Fill Word(On Active)   3
Fill Word(Current)     3
AL_PA Offset 13       ..
Trunk Port            ..
Long Distance         LE
VC Link Init          ON

HP:
Ports of Slot 0   23
-----------------+--
Speed             AN
Fill Word          0
AL_PA Offset 13   ..
Trunk Port        ..
Long Distance     LE
VC Link Init      ON

两台交换机版本相差比较大,版本如下:

华为SAN交换机版本
huawei_sns2124_3:admin> version
Kernel:     2.6.14.2  
Fabric OS:  v7.2.1
Made on:    Thu Dec 12 21:36:52 2013
Flash:      Thu Jan 8 18:50:47 2015
BootProm:   1.0.11

惠普SAN交换机版本:
brocade_hp_san:admin> version
Kernel:     2.6.14.2  
Fabric OS:  v6.2.0d
Made on:    Wed Mar 25 18:00:46 2009
Flash:      Sat May 15 11:59:42 2010
BootProm:   1.0.6

把两台交换机的流控都改成Receiver Ready (R_RDY),错误消失,级联成功。

更改方式如下(在两台交换机上都运行此命令):
portcfgislmode 23 1(此命令会停业务,务必小心操作)


END