S5700端口未接线缆但是每隔10分钟提示端口下有环路

发布时间:  2016-12-21 浏览次数:  668 下载次数:  0
问题描述

S5700GE0/0/1端口未接线缆但是每隔10分钟提示该端口下有环路,对业务无影响,一直告警,配置如下:

interface GigabitEthernet0/0/1

port link-type access

port default vlan 1572

loopback-detect packet vlan 1572

loopback-detect enable

#

 

接口状态如下:

GigabitEthernet0/0/1 current state : LOOPBACK-DETECT DOWN

 

Line protocol current state : DOWN

 

Description:

 

Switch Port, PVID : 1572, TPID : 8100(Hex), The Maximum Frame Length is 1600

 

IP Sending Frames' Format is PKTFMT_ETHNT_2, Hardware address is f84a-bff2-0a20

 

Current system time: 2015-11-18 08:52:25-05:13

 

Port Mode: COMMON COPPER

 

Speed :   10,  Loopback: NONE

 

Duplex: HALF,  Negotiation: ENABLE

 

Mdi   : AUTO

告警信息

#Nov 18 2015 10:32:12-05:13 chaihu_s5700 LBDT/4/PORTTRAP:OID 1.3.6.1.4.1.2011.5.25.174.3.3 Loopback does exist on interface(7)GigabitEthernet0/0/1 ( VLAN 1572 ) , loopback detect status: 3.(1:normal; 2:block; 3:shutdown; 4:trap; 5:nolearn)

 

#Nov 18 2015 10:32:12-05:13 chaihu_s5700 LBDT/4/PORTTRAP:OID 1.3.6.1.4.1.2011.5.25.174.3.3 Loopback does exist on interface(6)GigabitEthernet0/0/1 ( VLAN 1572 ) , loopback detect status: 3.(1:normal; 2:block; 3:shutdown; 4:trap; 5:nolearn)

处理过程

接口GE0/0/1口下设置的环回检测,当前版本默认环回检测处理动作为shutdown,根据当前的告警可确定,端口之前由于检测到对端有环路执行的shutdown的操作,并且产生相关告警,如动作未恢复,设备会一直告警;

若配置接口处理动作为shutdown,当环回消失后,被shutdown的接口不能自动恢复,需要依次执行命令shutdownundo shutdown手动恢复,或者执行命令restart重启接口。

根因

接口环回检测动作导致端口shutdown,未使用命令恢复端口状态,导致告警不消除,不断产生告警。

解决方案

依次执行命令shutdownundo shutdown手动恢复,或者执行命令restart重启接口。

建议与总结

不停产生与无物理链路的端口相关的告警,首先确认端口下有什么配置,如down之前就因为loopback-detect或者其他命令配置导致端口被执行的某些操作,不能自动恢复,请先查看端口状态,根据具体状态判断根因