Ne20E-X6与C友商路由器对接CPOS接口状态Down故障

发布时间:  2015-12-21 浏览次数:  136 下载次数:  3
问题描述

总部局点原为C友商7507路由器通过CPOS链路划分时隙与多个分支局点路由器互联,现总部局点7507设备替换为Ne20E-X6,在替换后发现对端为C友商路由器的分支局点串行口物理状态Down,协议Down

告警信息

1Ne20设备接口信息:

Serial3/0/1/51:0 current state : DOWN

Line protocol current state : DOWN

Description:HUAWEI, Serial3/0/1/51:0 Interface

Route Port,The Maximum Transmit Unit is 1500, Hold timer is 10(sec)

Derived from Cpos3/0/1 e1 51,  Timeslot(s) Used: 1-31,  baudrate is 1984000 bps

Internet Address is 192.168.1.201/30

Link layer protocol is nonstandard HDLC

Physical layer is Packet Over NO-CRC4     ////NE20默认成帧No-CRC4

 

2,原有C友商7507路由器接口:

Serial5/0/0.1/3/3/3:0 is up, line protocol is up

  Hardware is cyBus Channelized STM-1

  Internet address is 192.168.1.201/30

  MTU 1500 bytes, BW 1984 Kbit, DLY 20000 usec, rely 255/255, load 1/255

  Encapsulation HDLC, crc 16, loopback not set    ///默认校验位为16

 

3,不通的对端局点C友商1700路由器信息:

Router#show controllers e1

E1 0 is up.

  Applique type is Channelized E1 - balanced

  No alarms detected.

  alarm-trigger is not set

  Version info Firmware: 20011109, FPGA: 11

  Framing is CRC4, Line Code is HDB3, Clock Source is Line.    ////成帧默认为CRC4

处理过程

1,  替换设备后发现部分局点不通,查看接口状态发现物理Down

2,  经过统计发现仅有C友商设备局点状态为Down,协议封装和CPOS时隙均对应一致;

3,  查看对端局点设备接口信息发现E1成帧为CRC4,串行口CRC校验字长度为16位(见告警信息);

4,  经过查询Ne20设备E1默认成帧模式为no-CRC4,串行口CRC校验位为32位;

5,  执行以下命令将C友商设备对应的E1时隙修改为CRC4成帧,串口CRC校验位32位:

Sys

controller Cpos3/0/1

e1 51 set frame-format crc4

#

       interface Serial3/0/1/51:0

crc 16

6,  检查接口状态全UP,业务恢复正常。

根因

C友商路由器默认E1成帧为CRC4,串行口校验位默认16位,与华为路由器默认配置不一致导致故障。

解决方案

1,  替换设备后发现部分局点不通,查看接口状态发现物理Down

2,  经过统计发现仅有C友商设备局点状态为Down,协议封装和CPOS时隙均对应一致;

3,  查看对端局点设备接口信息发现E1成帧为CRC4,串行口CRC校验字长度为16位(见告警信息);

4,  经过查询Ne20设备E1默认成帧模式为no-CRC4,串行口CRC校验位为32位;

5,  执行以下命令将C友商设备对应的E1时隙修改为CRC4成帧,串口CRC校验位32位:

6,  检查接口状态全UP,业务恢复正常。

建议与总结

设备默认配置在配置脚本中不体现,各厂商设备默认参数各异,替换前要做好对比工作。

END