FAQ---S12708通过display ospf bfd session all查看,down状态的不同vlanif接口下参数Rx和Tx不同,Rx和Tx是如何计算

发布时间:  2015-12-22 浏览次数:  152 下载次数:  0
问题描述

Q:

   S12708通过display ospf bfd session all查看信息,down状态的不同vlanif接口下参数Rx和Tx不同,Rx和Tx是如何计算


[CDNCS001]display ospf bfd session all

 

         OSPF Process 1 with Router ID 172.31.100.110

 

         OSPF Process 3 with Router ID 10.185.248.1

  Area 0.0.0.0 interface 10.185.224.1(Vlanif1150)'s BFD Sessions

 

 NeighborId:10.185.248.3     AreaId:0.0.0.0          Interface:Vlanif1150

 BFDState:down               rx    :12000            tx       :12000

 Multiplier:0                BFD Local Dis:8205      LocalIpAdd:10.185.224.1

 RemoteIpAdd:10.185.224.2    Diagnostic Info:No diagnostic information

 

  Area 0.0.0.0 interface 10.185.224.9(Vlanif1152)'s BFD Sessions

 

 NeighborId:10.185.248.4     AreaId:0.0.0.0          Interface:Vlanif1152

 BFDState:down               rx    :14000            tx       :14000

 Multiplier:0                BFD Local Dis:8194      LocalIpAdd:10.185.224.9

 RemoteIpAdd:10.185.224.10   Diagnostic Info:No diagnostic information

 

  Area 0.0.0.0 interface 10.185.224.33(Vlanif1158)'s BFD Sessions

 

 NeighborId:10.185.248.2     AreaId:0.0.0.0          Interface:Vlanif1158

 BFDState:up                 rx    :1000             tx       :1000






解决方案

答复:


为降低对系统资源的占用,一旦检测到BFD会话Down,系统自动将本端的接收间隔调整为一个较大的随机值,该随机值介于1000015000毫秒之间,当BFD会话的状态重新变为Up后,再恢复成用户配置的时间间隔。

无灵活插卡时BFD报文接收间隔建议使用缺省值1000毫秒,如果修改过小会影响系统性能。

 

使用实例

# 配置BFD控制报文的期望接收间隔为50毫秒,配置前BFD会话bfd1已经创建。


<Quidway> system-view

[Quidway] bfd bfd1

[Quidway-bfd-session-bfd1] min-rx-interval 50



END