AR2240 配置静态路由后测试下一跳地址和出接口没有匹配

发布时间:  2015-12-30 浏览次数:  255 下载次数:  0
问题描述

AR2200配置了静态路由,但是tracert 目的网段地址并没有按照静态路由走

主要配置如下:

[Huawei]display cu
[V200R005C20SPC200]
#
interface Serial5/0/1
link-protocol ppp
ip address 192.16.151.9 255.255.255.252
#
interface Serial5/0/2
link-protocol ppp
ip address 192.16.151.13 255.255.255.252
#
ip route-static 10.0.0.0 255.0.0.0 Serial5/0/1 192.16.151.10
ip route-static 192.46.6.0 255.255.255.0 Serial5/0/2 192.16.151.14
ip route-static 192.46.27.0 255.255.255.0 Serial5/0/2 192.16.151.14
return
[Huawei]dis ip int bri
*down: administratively down
^down: standby
Interface                         IP Address/Mask      Physical   Protocol  
     
Serial5/0/1                       192.16.151.9/30      up         up 
      
Serial5/0/2                       192.16.151.13/30     up         up 
       
       
   

[Huawei]dis ip rout
[Huawei]dis ip routing-table
Route Flags: R - relay, D - download to fib
------------------------------------------------------------------------------
Routing Tables: Public
         Destinations : 38       Routes : 39      

Destination/Mask    Proto   Pre  Cost      Flags NextHop         Interface 

     192.46.6.0/24  Static  60   0           D   192.16.151.14   Serial5/0/2 
     192.46.27.0/24  Static  60   0           D   192.16.151.14   Serial5/0/2 
     
[Huawei]tracert 192.46.27.66
traceroute to  192.46.27.66(192.46.27.66), max hops: 30 ,packet length: 40,press CTRL_C to break
1 192.16.151.10 5 ms  5 ms  5 ms                           
2 192.16.151.10 5 ms  !H *  7 ms  !H
[Huawei]tracert 192.46.6.66
traceroute to  192.46.6.66(192.46.6.66), max hops: 30 ,packet length: 40,press CTRL_C to break
1 192.16.151.10 6 ms  5 ms  5 ms
2  * 192.16.151.10 6 ms  !H *

从上面的tracert 结果看,到192.46.27.0和192.46.6.0本来应该走192.16.151.14 ,但实际却走了192.16.151.10 的下一跳

 

处理过程
1、排查是否有重定向等配置
检查配置,并未发现有重定向配置

2、排查路由优先级
当前配置只配了静态路由,且路由优先级都是默认的60

3、由于这是ppp的链路,配置路由的时候可以不写下一跳地址,怀疑目前出接口是对的,但是下一跳是错误的,通过如下测试,查看网关的出口是否正确。

如下:

 [Huawei]dis ip routing-table 192.16.151.14
    
Destination/Mask    Proto   Pre  Cost      Flags NextHop         Interface 

  192.16.151.14/32  Direct  0    0           D   192.16.151.14   Serial5/0/3
[Huawei]dis ip routing-table 192.16.151.10

192.16.151.10/32  Direct  0    0           D   192.16.151.10   Serial5/0/2


从上面的测试结果,可以很明显的看出,到网关14走的不是Serial5/0/2,而到10走的是Serial5/0/2
从而判断是线接错了。

根因
线接错的原因导致
解决方案

调整线路 192.16.151.14对应的出接口为Serial5/0/2后问题解决
建议与总结

遇到这样的问题,看似问题很奇怪,但是通过上述的排查方法,还是很容易发现问题的根因。

END