RM记录MCU经常离线

发布时间:  2016-02-03 浏览次数:  184 下载次数:  0
问题描述
MCURMMCU管理里经常离线,但是会议没中断,MCUweb页面也没有什么告警,此现象已出现多次。
处理过程

1、现场调会,查看是否有异常告警

2、查看MCU日志,发现有MCU IP地址冲突告警,所以应该是网络存在IP冲突导致MCU网络异常,从而使得MCUSMC数据不同步.

·        2015-08-11 16:26:30|Notice|main|CPUID=0x0|GE0 ip conflit,remote mac:00:03:2e:0d:00:4b
2015-08-11 16:28:46|Notice|main|CPUID=0x0|GE0 ip conflit,remote mac:00:03:2e:0d:00:4b
2015-08-11 16:33:46|Notice|main|CPUID=0x0|GE0 ip conflit,remote mac:00:03:2e:0d:00:4b
2015-08-11 16:38:22|Notice|main|CPUID=0x0|GE0 ip conflit,remote mac:00:03:2e:0d:00:4b
2015-08-11 16:43:46|Notice|main|CPUID=0x0|GE0 ip conflit,remote mac:00:03:2e:0d:00:4b
2015-08-11 16:47:26|Notice|main|CPUID=0x0|GE0 ip conflit,remote mac:00:03:2e:0d:00:4b
2015-08-11 16:48:47|Notice|main|CPUID=0x0|GE0 ip conflit,remote mac:00:03:2e:0d:00:4b
2015-08-11 16:53:48|Notice|main|CPUID=0x0|GE0 ip conflit,remote mac:00:03:2e:0d:00:4b
2015-08-11 16:58:47|Notice|main|CPUID=0x0|GE0 ip conflit,remote mac:00:03:2e:0d:00:4b
2015-08-11 17:03:48|Notice|main|CPUID=0x0|GE0 ip conflit,remote mac:00:03:2e:0d:00:4b

注意查看MCU的告警类日志。

注意基本信息的获取:设备告警信息,设备日志等。

MCU IP地址存在冲突时,MCU会有告警显示:

 

根因
MCU IP地址冲突
解决方案
排除IP地址冲突之后,问题解决.
建议与总结


END