问题描述
NE40E主备引擎手工切换时,直连的C友商路由器的pos接口会down/up一次,大约1-2秒闪断,流量丢失业务短时间受影响,如下所示:
*Sep 7 18:50:38.103: %LINEPROTO-5-UPDOWN: Line protocol on Interface POS1/0, changed state to down
*Sep 7 18:51:48.103: %LINEPROTO-5-UPDOWN: Line protocol on Interface POS1/0, changed state to up
告警信息
处理过程

第一步,检查NE40E和C友商pos接口下的链路层协议、CRC、MTU、Scramble等配置,结果一致
<HUAWEI> display interface pos 1/0/0
  Pos1/0/0 current state : UP
  Line protocol current state : UP
  Route Port,The Maximum Transmit Unit is 4470 bytes, Hold timer is 10(sec)
  Link layer protocol is PPP
  Physical layer is Packet Over SONET,
  Scramble disabled, clock master, CRC-32, loopback: none
Cisco#show interfaces pos1/0
  POS1/0 is up, line protocol is up
  Hardware is Packet over Sonet
  MTU 4470 bytes, BW 155000 Kbit, DLY 100 usec,
  Encapsulation PPP, LCP Open
  Open: CDPCP, crc 32, loopback not set
  Keepalive set (10 sec)
  Scramble disabled

第二步,由于缺省的Clock配置使两端的pos接口能正常up,所以一直忽略和未考虑Clock的因素。通过检查NE40E和C友商pos接口下Clock的配置,发现两端pos接口是“主-主”模式,试着改成“主-从”模式后不再出现此现象。分析原因在于NE40E路由器主备引擎手工切换时业务板会先去跟引擎的Clock同步,再与C友商的路由器pos接口协商,偶尔Clock信号超过一定的时间,就会导致pos接口down/up一次。

根因
解决方案
通过把两端pos接口的Clock修改成“主-从”模式,从而解决NE40E路由器主备引擎手工切换时C友商POS接口down/up问题。
方法一:
[HUAWEI]interface pos0/0/0
[HUAWEI-Pos0/0/0]clock master
Cisco(config)#interface pos 1/0
Cisco(config-if)#clock source line
方法二:
[HUAWEI]interface pos0/0/0
[HUAWEI-Pos0/0/0]clock slave
Cisco(config)#interface pos 1/0
Cisco(config-if)#clock source internal
建议与总结
NE40E和C友商路由器的pos接口Clock在“主-主”模式下,虽然接口能up,建议手工修改成“主-从”模式,否则NE40E路由器主备引擎手工切换时C友商POS接口偶尔会出现down/up问题。