S5720EI V2R7 vlanif接口下配置statistic enable统计不到出方向流量

发布时间:  2016-12-22 浏览次数:  399 下载次数:  0
问题描述

S5720EI,设备版本V2R7,在vlanif接口下使能statistic enable之后只能统计到入方向流量,无法统计到出方向流量

配置如下:

interface Vlanif130
statistic enable both

vlan 130
statistic enable
traffic-policy p1 inbound
traffic-policy p1 outbound

现display interface vlanif 130如下

Vlanif130 current state : UP
Line protocol current state : UP
Last line protocol up time : 2016-04-16 08:14:07 UTC+08:00
Description:"ZhongXin(SMIC) at 40M+10M (SIN0011095)"
Route Port,The Maximum Transmit Unit is 1500
Internet Address is 202.122.114.145/30
Internet Address is 61.8.42.241/30 Sub
IP Sending Frames' Format is PKTFMT_ETHNT_2, Hardware address is 845b-1259-8e5b
Current system time: 2016-05-24 17:54:41+08:00
Last 300 seconds input rate 3542488 bits/sec, 1106 packets/sec
Last 300 seconds output rate 0 bits/sec, 0 packets/sec
Input:  4860390 packets, 2458671191 bytes
Output:  0 packets, 0 bytes
    Input bandwidth utilization  : --
    Output bandwidth utilization : --

只能看到input方向流量,无法看到出方向流量。

处理过程

1、确认statistic enable命令用法,若VLANIF接口对应的VLAN下使能了流量统计功能,则该VLANIF接口outbound方向的流量统计功能不生效

据此删除vlan 130下的statistic enable之后测试,删除之后vlanif 130出方向依旧统计不到流量

2、再次确认配置,vlan 130出方向还调用了traffic policy,查看traffic policy配置

traffic classifier c1 operator and
if-match vlan-id 130
#
traffic behavior b1
car cir 51200 pir 51200 cbs 6400000 pbs 6400000 green pass yellow pass red discard
statistic enable
#
traffic policy p1 match-order config
classifier behavior
发现流行为中配置了statistic enable,怀疑是流行为中的statistic enable影响,删除之后再次测试

3、删除流行为中的statistic enable之后,display interface vlanif 130出方向成功统计到流量

根因

由于vlan 130下调用了流策略,而该流策略中的流行为配置了statistic enable导致vlanif130接口出方向无法统计到流量

从这个角度可以说明针对出方向统计流量时,流策略统计优先级高于vlan统计和vlanif接口统计

解决方案
删除vlan130出方向调用策略里流行为中的statistic enable之后,成功统计到vlanif 130出方向流量
建议与总结

目前仅S5720EI和S5720HI支持statistic enable统计vlanif接口流量

注意事项:

1、若VLANIF接口对应的VLAN下使能了流量统计功能,则该VLANIF接口outbound方向的流量统计功能不生效

2、流策略统计优先级高于vlan统计和vlanif统计优先级

END