S9706 V200R008C00SPC500 堆叠备框备用主控板不能注册

发布时间:  2016-06-17 浏览次数:  81 下载次数:  0
问题描述
S9706 V200R008C00SPC500 堆叠备框备用主控板不能注册
告警信息

===============display device===============
==================================================
Chassis 1 (Master Switch)
S9706's Device status:
Slot  Sub Type         Online    Power      Register       Status     Role 
-------------------------------------------------------------------------------
1     -   EH1D2G24SEC0 Present   PowerOn    Registered     Normal     NA   
2     -   EH1D2G48TFA0 Present   PowerOn    Registered     Normal     NA   
3     -   EH1D2G48TFA0 Present   PowerOn    Registered     Normal     NA   
7     -   EH1D2SRUC000 Present   PowerOn    Registered     Normal     Master
      1   EH1D2VS08000 Present   PowerOn    Registered     Normal     NA   
8     -   EH1D2SRUC000 Present   PowerOn    Registered     Normal     Slave
      1   EH1D2VS08000 Present   PowerOn    Registered     Normal     NA   
PWR1  -   -            Present   PowerOn    Registered     Normal     NA   
PWR2  -   -            Present   PowerOn    Registered     Normal     NA   
CMU1  -   EH1D200CMU00 Present   PowerOn    Registered     Normal     Master
FAN1  -   -            Present   PowerOn    Registered     Normal     NA   
FAN2  -   -            Present   PowerOn    Registered     Normal     NA   
Chassis 2 (Standby Switch)
S9706's Device status:
Slot  Sub Type         Online    Power      Register       Status     Role 
-------------------------------------------------------------------------------
1     -   EH1D2G24SEC0 Present   PowerOn    Registered     Normal     NA   
2     -   EH1D2G48TFA0 Present   PowerOn    Registered     Normal     NA   
3     -   EH1D2G48TFA0 Present   PowerOn    Registered     Normal     NA   
7     -   EH1D2SRUC000 Present   PowerOn    Registered     Normal     Master
      1   EH1D2VS08000 Present   PowerOn    Registered     Normal     NA   
8     -   -            Present   PowerOn    Unregistered   -          Slave
PWR1  -   -            Present   PowerOn    Registered     Normal     NA   
PWR2  -   -            Present   PowerOn    Registered     Normal     NA   
CMU1  -   EH1D200CMU00 Present   PowerOn    Registered     Normal     Master
FAN1  -   -            Present   PowerOn    Registered     Normal     NA   
FAN2  -   -            Present   PowerOn    Registered     Normal     NA   
<SIMT>

Chassis 2  8槽位单板状态为Unregistered

 

处理过程

1.首先检查版本是否支持该EH1D2SRUC板卡,手册板卡和版本配套关系显示支持

2.检查板卡无弯针,拔插单板仍然不能注册。

3.查看设备相关reason 和日志信息

Jun 17 2016 12:20:51 SIMT CSSM/2/CSSVS08CONNECTERR:OID 1.3.6.1.4.1.2011.5.25.183.3.3.2.15 The connection between CSS port 1/7/0/6 and 2/7/0/6 is incorrect. 1/7/0/6 belongs to group 2 of slot1/7 and should be connected to a port in group 2 of slot2/8. 2/7/0/6 belongs to group 2 of slot2/7 and should be connected to a port in group 2 of slot1/8. (group 1: 1-4 group 2: 5-8)

 The MPU chassis[1] board[8]'s reset time is 2 in total. Detailed information:

--  1. 2016/06/17   12:20:37, Reset No.: 2

       Reason: Reset for no right link to the remote chassis

--  2. 2016/06/17   12:04:59, Reset No.: 1

       Reason: Reset for no right link to the remote chassis

Info: The MPU chassis[2] board[7] does not have reset records.

The MPU chassis[2] board[8]'s reset time is 1 in total. Detailed information:

--  1. 2016/06/17   12:20:27, Reset No.: 1

       Reason: Reset for the CSS card is pullout

发现2/8重启原因是子卡拔出。尝试板卡下电后拔插子卡,故障解决,单板能正常注册。

根因

由于子卡没有插好,触发母板的使用限制,最终导致板卡不能正常注册


解决方案

板卡下电重新拔插子卡

建议与总结

板卡不能注册首先检查版本是否支持,对板卡的使用限制特别要注意。