S9700交换机集群卡方式集群后,备框的备用主控板注册不上

发布时间:  2016-06-25 浏览次数:  123 下载次数:  0
问题描述

S9700交换机集群卡方式集群后,备框的备用主控板注册不上:


==================================================
  ===============display device===============
==================================================
Chassis 1 (Master Switch)
S9706's Device status:
Slot  Sub Type         Online    Power      Register       Status     Role 
-------------------------------------------------------------------------------
1     -   EH1D2G48SX1E Present   PowerOn    Registered     Normal     NA   
2     -   EH1D2S08SX1E Present   PowerOn    Registered     Normal     NA   
7     -   EH1D2SRUC000 Present   PowerOn    Registered     Normal     Master
      1   EH1D2VS08000 Present   PowerOn    Registered     Normal     NA   
8     -   EH1D2SRUC000 Present   PowerOn    Registered     Normal     Slave
      1   EH1D2VS08000 Present   PowerOn    Registered     Normal     NA   
PWR1  -   -            Present   PowerOn    Registered     Normal     NA   
PWR2  -   -            Present   PowerOn    Registered     Normal     NA   
CMU1  -   EH1D200CMU00 Present   PowerOn    Registered     Normal     Master
FAN1  -   -            Present   PowerOn    Registered     Normal     NA   
FAN2  -   -            Present   PowerOn    Registered     Normal     NA   
Chassis 2 (Standby Switch)
S9706's Device status:
Slot  Sub Type         Online    Power      Register       Status     Role 
-------------------------------------------------------------------------------
1     -   EH1D2G48SX1E Present   PowerOn    Registered     Normal     NA   
2     -   EH1D2S08SX1E Present   PowerOn    Registered     Normal     NA   
7     -   EH1D2SRUC000 Present   PowerOn    Registered     Normal     Master
      1   EH1D2VS08000 Present   PowerOn    Registered     Normal     NA   
8     -   -            Present   PowerOn    Unregistered   -          Slave
PWR1  -   -            Present   PowerOn    Registered     Normal     NA   
PWR2  -   -            Present   PowerOn    Registered     Normal     NA   
CMU1  -   EH1D200CMU00 Present   PowerOn    Registered     Normal     Master
FAN1  -   -            Present   PowerOn    Registered     Normal     NA   
FAN2  -   -            Present   PowerOn    Registered     Normal     NA 

告警信息
Jun  1 2016 13:19:22 s9706-2 %%01ALML/4/ENTRESET(l)[16]:MPU frame[1] board[8] is reset. The reason is: Reset for no right link to the remote chassis.
处理过程
根据告警提示:
Jun  1 2016 13:19:22 s9706-2 %%01ALML/4/ENTRESET(l)[16]:MPU frame[1] board[8] is reset. The reason is: Reset for no right link to the remote chassis.
由于错误的连线导致8号槽位主控板复位,后续排查集群卡的连接,核实到2/8槽位主控的集群卡到1/7槽位主控的集群卡没连线导致注册不上。
根因
集群卡连接方式错误导致。
解决方案
系统备框的主控板集群卡都必须和系统主框的主用主控板集群卡连接,备框的主控板才能正常注册,将2/8槽位主控的集群卡到1/7槽位主控的集群卡连线后解决。
建议与总结

S9700集群卡方式集群,连线时严格遵循连接规则:

EH1D2VS08000(S9700)连接规则 

说明:

每块集群卡有8个SFP+接口,分两组(1~4和5~8)。组与组之间按照图示要求连接,组内接线顺序无限制,每组内至少连接一根线缆,建议全连接。

END