S7700堆叠,服务器之间相互ping不通,关闭备交换机ping正常

发布时间:  2016-06-29 浏览次数:  256 下载次数:  0
问题描述


S7700 V200R008C00SPC500

S7700堆叠(链路聚合)----友商交换机/服务器


总计十台服务器,网关都在S7700上,每台服务器四块网卡ETH-trunk与交换机互联。每台服务器创建了多个虚拟机及一个虚拟交换机,虚拟机的虚拟网卡网关在虚拟交换机上。跨服务器虚拟网卡之间互ping,无法ping通。

大致配置如下:

#
interface Vlanif10
ip address 172.27.83.254 255.255.255.0
#
interface Eth-Trunk10
port default vlan 10
#
interface GigabitEthernet1/2/0/0
eth-trunk 10
#
interface GigabitEthernet1/2/0/1
eth-trunk 10
#
interface GigabitEthernet2/2/0/0
eth-trunk 10
#
interface GigabitEthernet2/2/0/1
eth-trunk 10
#

告警信息
#Jun 27 2016 17:57:33 WJW-Center-S7706-PR L2IFPPI/4/MAC_FLAPPING_ALARM:OID 1.3.6.1.4.1.2011.5.25.42.2.1.7.12 The MAC address has flap value. (L2IfPort=0, entPhysicalIndex=0, BaseTrapSeverity=4, BaseTrapProbableCause=549, BaseTrapEventType=1, MacAddr=0050-56b8-eea4, VLANID=10, FormerIfDescName=Eth-Trunk50, CurrentIfDescName=Eth-Trunk15, DeviceName=WJW-Center-S7706-PR)
#Jun 27 2016 17:52:13 WJW-Center-S7706-PR L2IFPPI/4/MAC_FLAPPING_ALARM:OID 1.3.6.1.4.1.2011.5.25.42.2.1.7.12 The MAC address has flap value. (L2IfPort=0, entPhysicalIndex=0, BaseTrapSeverity=4, BaseTrapProbableCause=549, BaseTrapEventType=1, MacAddr=0050-56b8-44bd, VLANID=10, FormerIfDescName=Eth-Trunk19, CurrentIfDescName=Eth-Trunk50, DeviceName=WJW-Center-S7706-PR)
处理过程

1、当前环境为链路聚合双上行,关闭从框,业务就能恢复正常,由于不确定对端设备配置形态,初步分析可能原因:

a、链路丢包或者设备丢包,做流统,统计丢包点

b、环路,由于对端未聚合或者其他原因导致网络环路

2、查看S77端口计数,无错包、丢包计数,排除物理链路原因,需要进一步配置流量统计查看;

3、同时查看告警、日志,发现大量mac飘移记录,关闭从框的时间段无飘移告警,初步确定为飘移接口的接口下设备环路

查看mac飘移记录,确定飘移时间点都是在从框正常上电时的记录:

=======================================================================
  ===============display mac-address flapping record===============
=======================================================================
Total items on slot 1/2: 2

-------------------------------------------------------------------------------
Move-Time                 VLAN MAC-Address  Original-Port  Move-Ports   MoveNum
-------------------------------------------------------------------------------
S:2016-06-27 16:38:02     1    28d2-441b-25d0 Eth-Trunk50   Eth-Trunk20  138 
E:2016-06-27 16:39:23
  ===============display arp track===============

D  172.27.83.155   0050-56ac-2b6c 10   Eth-Trunk13               06-27 16:32:40
M  172.27.83.4     0050-56b8-5d36 10   Eth-Trunk13  Eth-Trunk50  06-27 16:32:56
D  172.27.83.8     0050-56b8-760d 10   Eth-Trunk15               06-27 16:33:00
D  172.27.83.2     0050-56b8-eea4 10   Eth-Trunk15               06-27 16:33:00
D  172.27.83.247   28d2-441b-25d0 10   Eth-Trunk20               06-27 16:33:42
M  172.27.83.4     0050-56b8-5d36 10   Eth-Trunk50  Eth-Trunk13  06-27 16:33:52
M  172.27.83.155   0050-56ac-2b6c 10   Eth-Trunk13  Eth-Trunk50  06-27 16:38:03
M  172.27.83.15    0050-56b8-5fca 10   Eth-Trunk50  Eth-Trunk12  06-27 16:39:42

从新排查组网,发现下行交换机与服务器之间错误连线导致环路,排除后问题解决

根因
服务器与交换机之间错误连线导致环路
解决方案
排查具体网络连线,排除环路恢复正常
建议与总结

堆叠设备通常与对端为链路聚合互联,这种情况,注意两端务必都是链路聚合,多个聚合口的情况下,注意连线,连接错误很可能导致环路

END