华为S9312对接锐捷和思科设备导致网络环路,CUP和接口利用率爆表

发布时间:  2016-07-24 浏览次数:  175 下载次数:  1
问题描述

华为S9312上行和思科6650对接的时候,产生环路CPU利用率过高,产生告警信息,下行和锐捷对接的时候也是产生了CPU告警。

告警信息

[S9312_M]dis int b 

PHY: Physical

*down: administratively down

(l): loopback

(s): spoofing

(b): BFD down

(e): ETHOAM down

(dl): DLDP down

(d): Dampening Suppressed

InUti/OutUti: input utility/output utility

Interface                   PHY   Protocol InUti OutUti   inErrors  outErrors

GigabitEthernet0/0/1        up    up          95%     95%          0          0

GigabitEthernet0/0/2        down  down        0%     0%          0          0

GigabitEthernet0/0/3        down  down        0%     0%          0          0

GigabitEthernet0/0/4        down  down        0%     0%          0          0

GigabitEthernet0/0/5        down  down        0%     0%          0          0

GigabitEthernet0/0/6        down  down        0%     0%          0          0

GigabitEthernet0/0/7        down  down        0%     0%          0          0

GigabitEthernet0/0/8        down  down        0%     0%          0          0

GigabitEthernet0/0/9        down  down        0%     0%          0          0

GigabitEthernet0/0/10       down  down        0%     0%          0          0

GigabitEthernet0/0/11       down  down        0%     0%          0          0

GigabitEthernet0/0/12       down  down        0%     0%          0          0

GigabitEthernet0/0/13       down  down        0%     0%          0          0

GigabitEthernet0/0/14       down  down        0%     0%          0          0

GigabitEthernet0/0/15       down  down        0%     0%          0          0

GigabitEthernet0/0/16       down  down        0%     0%          0          0

GigabitEthernet0/0/17       down  down        0%     0%          0          0

GigabitEthernet0/0/18       down  down        0%     0%          0          0

GigabitEthernet0/0/19       down  down        0%     0%          0          0

GigabitEthernet0/0/20       down  down        0%     0%          0          0

GigabitEthernet0/0/21       down  down        0%     0%          0          0

GigabitEthernet0/0/22       down  down        0%     0%          0          0

GigabitEthernet0/0/23       down  down        0%     0%          0          0

GigabitEthernet0/0/24       down  down        0%     0%          0          0

  ---- More ----

[S9312_M]dis cpu-usage

CPU Usage Stat. Cycle: 60 (Second)

CPU Usage            : 90% Max: 100%

CPU Usage Stat. Time : 2014-11-09  15:36:59 

CPU utilization for five seconds: 90%: one minute: 90%: five minutes: 90%.

GEMR                  0%         0/       0       GEMRun task                  

UTSK                  0%         0/       0       UTSK                         

APP                   0%         0/       0       APP                          

IP                    0%         0/  6e7feb       IP                           

EOAM                  0%         0/  748418       EOAM1AG                      

LINK                  0%         0/ 1673896       LINK                         

STP                   90%         0/ 72e9718       STP                          

VRPT                  0%         0/  7cda1b       VRPT                         

HOTT                  0%         0/       0       HOTT                         

TNQA                  0%         0/  85b0a5       TNQAC                        

TTNQ                  0%         0/       0       TTNQAS                       

TARP                  0%         0/       0       TARPING                      

TTVP                  0%         0/       0       TTVPLS                       

L2                    0%         0/ 307ae85       L2                           

VRRP                  0%         0/ 573043d       VRRP                         

L2_P                  0%         0/ 54de778       L2_PR                        


处理过程

1、 华为设备上启用STP模式为STP,在锐捷上也使用标准STP协议,

2、 由于要做VRRP,且网关也在S9312上面,在思科6650上面把STP的优先级改低,把S9312作为STP的根桥

3、 对接思科的时候把协议切换成标准的STP,查看对接是否还有环路存在,若有,则把锐捷和思科、S9312都切换成MSTP,修改不同的VLAN的根


根因

1、 思科6650和华为S9312在启用STP的过程中,分别配置了双STP主,双主抢占方式不一样,导致了环路产生

2、 思科和华为设备对接STP不兼容导致的问题,华为的MSTP和思科的MSTP存在问题

3、 锐捷的默认启动STP,华为的是MSTP,且锐捷的和华为的MSTP不兼容


解决方案

修改华为STP模式

建议与总结

对接不同厂家设备的时候,一定要注意其协议的兼容性,不要盲目对接,不然很容易导致对接故障,CPU等市盈率过高,导致设备故障。

END