ME60通过display power不显示AC电源状态

发布时间:  2016-10-27 浏览次数:  95 下载次数:  0
问题描述

ME60通过EPS200-4850A交流配电,通过display power不显示AC电源状态。

 

异常设备显示情况:

<QDHX-WK-BAS-ME60-03> display power 
No Present mode State                                             Num
-------------------------------------------------------------------------------
16 Yes     DC   Normal                                  Abnormal(0)/Normal(2)
17 Yes     DC   Normal                                  Abnormal(0)/Normal(2)
Power monitor cable state:
 Plug

 

正常设备显示情况:

<QDHX-DHL-BAS-ME60-01> display power 
No Present mode State                                             Num
-------------------------------------------------------------------------------
AC:
16 Yes     AC   Normal                                  Abnormal(0)/Normal(2)
17 Yes     AC   Normal                                  Abnormal(0)/Normal(2)
Power monitor cable state:
 Plug

PEM:
16 Yes     DC   Normal                                  Abnormal(0)/Normal(2)
17 Yes     DC   Normal                                  Abnormal(0)/Normal(2)
Power monitor cable state:
 Plug

解决方案

设备启动后插的监控线,导致设备无法监控到AC电源信息,需使用命令恢复监控:reset mbus slot 主用主控槽位号

END