S5700-28P-LI 端口数量不足,命令查询只有26个端口

发布时间:  2016-11-29 浏览次数:  174 下载次数:  0
问题描述

S5700-28P-LI   V200R001C00SPC300

设备之前已使用过,由于机房搬迁,停用了一段时间,再次使用发现,只能配置26个端口,还有两个端口无法发现,和设备型号不符:

===============display device===============
==================================================
S5700-28P-PWR-LI-AC's Device status:
Slot  Sub  Type         Online    Power      Register       Status     Role 
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
0     -    5728P-PWR    Present   PowerOn    Registered     Normal     Master

  ===============display interface brief===============
===========================================================
PHY: Physical
*down: administratively down
(l): loopback
(s): spoofing
(b): BFD down
(e): ETHOAM down
(dl): DLDP down
(d): Dampening Suppressed
InUti/OutUti: input utility/output utility
Interface                   PHY   Protocol InUti OutUti   inErrors  outErrors
GigabitEthernet0/0/1        down  down        0%     0%          0          0
GigabitEthernet0/0/2        down  down        0%     0%          0          0
GigabitEthernet0/0/3        down  down        0%     0%          0          0
GigabitEthernet0/0/4        down  down        0%     0%          0          0
GigabitEthernet0/0/5        down  down        0%     0%          0          0
GigabitEthernet0/0/6        down  down        0%     0%          0          0
GigabitEthernet0/0/7        down  down        0%     0%          0          0
GigabitEthernet0/0/8        down  down        0%     0%          0          0
GigabitEthernet0/0/9        down  down        0%     0%          0          0
GigabitEthernet0/0/10       down  down        0%     0%          0          0
GigabitEthernet0/0/11       down  down        0%     0%          0          0
GigabitEthernet0/0/12       down  down        0%     0%          0          0
GigabitEthernet0/0/13       down  down        0%     0%          0          0
GigabitEthernet0/0/14       down  down        0%     0%          0          0
GigabitEthernet0/0/15       down  down        0%     0%          0          0
GigabitEthernet0/0/16       down  down        0%     0%          0          0
GigabitEthernet0/0/17       down  down        0%     0%          0          0
GigabitEthernet0/0/18       down  down        0%     0%          0          0
GigabitEthernet0/0/19       down  down        0%     0%          0          0
GigabitEthernet0/0/20       down  down        0%     0%          0          0
GigabitEthernet0/0/21       down  down        0%     0%          0          0
GigabitEthernet0/0/22       down  down        0%     0%          0          0
GigabitEthernet0/0/23       down  down        0%     0%          0          0
GigabitEthernet0/0/24       down  down        0%     0%          0          0
GigabitEthernet0/0/25       down  down        0%     0%          0          0
GigabitEthernet0/0/26       down  down        0%     0%          0          0
NULL0                       up    up(s)       0%     0%          0          0
Vlanif1                     down  down        --     --          0          0


告警信息

Jun 24 2016 17:14:56+08:00 Quidway ECM/3/STACKPORTISDOWN:OID 1.3.6.1.4.1.2011.5.25.183.1.22.11 stack port GigabitEthernet0/0/27 is down.

Jun 24 2016 17:14:56+08:00 Quidway ECM/3/STACKPORTISDOWN:OID 1.3.6.1.4.1.2011.5.25.183.1.22.11 stack port GigabitEthernet0/0/28 is down.

处理过程

设备硬件出厂都会有检测,不可能存在端口号数量与实际产品型号不符的情况,当前型号为24个电口+4个光口,前连个光口能识别,后两个光口无法识别,由于最初设备应用场景已无法确认,初步怀疑接口芯片或者其他配置导致

查看G0/0/27、28端口号相关告警,发现这两个端口为堆叠口,根因确认,堆叠口本身无法dis int brief查看,得用dis stack port查看,当前已无设备堆叠,删除堆叠配置后,端口查询正常

根因

G0/0/27、28端口被加入堆叠口

解决方案

删除堆叠配置

建议与总结

设备堆叠后单纯的reset save清空配置,堆叠配置是无法清空的,如之前堆叠设备拆分后需要单独使用,请注意删除堆叠相关配置

END