What's the electromagnetic compatibility requirements for the proper running of the server

Publication Date:  2016-12-02 Views:  367 Downloads:  0
Issue Description
What's the electromagnetic compatibility requirements for the proper running of the server
Solution
Electromagnetic Phenomenon                                          Specifications

Low frequency magnetic field             Frequency (Hz)             50-20,000
                                         Ampl. A/m (rms)            0.025-10

Amplitude modulation RF electric field   Frequency (MHz)            0.009-18,000
                                         Ampl. V/m (rms)            < 3

Pulse modulation RF electric field       Frequency (GHz)            1-18
                                         Ampl. (V/m (peak))         < 3

END