发布时间:  2016-12-10 浏览次数:  211 下载次数:  0
问题描述

问题描述:

1、AR2200路由器E1接口Serial3/0/0通过传输与H厂家路由器对接,物理状态DOWM,协议状态DOWN。

告警信息
处理过程

处理步骤一:

将E1接口Serial3/0/0通过命令fe1 loopback local内环,确认:接口状态UP,协议检测到环路:PPP link was closed because loopback was detected when LCP was negotiating。说明设备接口Serial3/0/0工作正常。

处理步骤二:

将连接接口Serial3/0/0的线缆手外环,确认:接口状态UP,协议检测到环路:PPP link was closed because loopback was detected when LCP was negotiating。说明连接接口Serial3/0/0的线缆工作正常。

处理步骤三:

查看接口Serial3/0/0状态display interface Serial3/0/0
Serial3/0/0 current state : DOWN
Line protocol current state : DOWN
Description:D2.ZDTGF-D2.FQB-2M
Route Port,The Maximum Transmit Unit is 1500, Hold timer is 10(sec)
Internet Address is 32.3.174.62/30
Link layer protocol is PPP
LCP initial
Timeslot(s) Used: 1-31,baudrate is 1984000 bps//通过elabel确认单板类型为E1-F类型,时隙使用1-31说明为成帧模式。而对端为非成帧模式。
Last physical up time   : 2016-11-04 14:55:58
Last physical down time : 2016-11-04 14:56:07

根因

AR2200路由器E1-F单板接口Serial3/0/0工作在成帧模式(1-31时隙,0时隙用作信令通道),对端设备工作在非成帧模式、

解决方案

接口Serial3/0/0下执行命令fe1 unframed,将E1-F接口Serial3/0/0的工作方式改为非成帧方式,物理接口工作正常。
建议与总结