S5720-28P-SI-AC做AS无法在parent上线

发布时间:  2017-03-08 浏览次数:  235 下载次数:  0
问题描述

S5720-28P-SI-AC做AS无法在parent上线

告警信息

parent设备S7706最近时间点日志如下,GigabitEthernet2/5/0/34和GigabitEthernet1/5/0/34属于eth-trunk48成员接口

#Mar  6 2017 15:11:03 GuiGang-YangXiang-S7706-A MBR/5/CONNECTERROR:OID 1.3.6.1.4.1.2011.5.25.327.31.3.2.1

 Connection error on the fabric-port in unified management. (Reason=Port check failed.(GigabitEthernet2/5/0/34))


#Mar  6 2017 15:11:03 GuiGang-YangXiang-S7706-A MBR/5/CONNECTERROR:OID 1.3.6.1.4.1.2011.5.25.327.31.3.2.1

 Connection error on the fabric-port in unified management. (Reason=Port check failed.(GigabitEthernet1/5/0/34))


处理过程

S7706 V200R009C00SPC500集群为parent,S5720-28P-SI-AC V200R008C00SPC500 作为一级AS接入。查看设备基本配置正确,

S7706通过ETH-trunk48连接AS,parent无法查看到AS上线。

<GuiGang-YangXiang-S7706-A>disp as unauthorized  record 

Unauthorized AS record:

--------------------------------------------------------------------------------

Total: 0


<GuiGang-YangXiang-S7706-A>>disp as all

Total: 0, Normal: 0, Fault: 0, Idle: 0, Version mismatch: 0

--------------------------------------------------------------------------------

No.  Type           MAC            IP              State        Name

--------------------------------------------------------------------------------

根因

告警:Port check failed,AS使用不支持端口连接Parent。

经确认S5720-28P-SI-AC是GE0/0/23和GE0/0/24口连接S7706,此两接口属于下行口。V200R008版本及以前版本,

AS仅可以使用上行口插卡口连接上游Parent或AS,不可以使用下行业务口连接上游Parent或AS;

V200R009版本开始,AS的下行业务口也可以连接上游Parent或AS,但是需要通过命令

uni-mng up-direction fabric-port interface interface-type interface-number [ to interface-number ]来配置。


S5720-28P-SI-AC命名规则如下,即GE0/0/25至GE0/0/28为上行口。

P:表示上行接口为交换机上固定的千兆光口。

解决方案
使用设备GE0/0/25至GE0/0/28上行口连接parent,或者升级至V2R9版本,通过命令

uni-mng up-direction fabric-port interface interface-type interface-number [ to interface-number ]来配置。


建议与总结

结合SVF部署注意事项及相关日志定位。

END