FusionCompute主机添加数据存储任务卡在90%

发布时间:  2017-03-09 浏览次数:  139 下载次数:  0
问题描述

在FusionCompute上对主机进行添加数据存储操作任务卡在90%,如图:

处理过程

1、分析主机NC日志,发现有很多光纤链路中断的告警

[2017-03-08 15:18:39,889] [INFO ] [002587] [003489] [vbs_sysfs.c 2241] [BSB] report alarm, addinfo:FAIL_FIBER_CHANNEL=, alarm_type:1, alarm_id:15.1005005, alarm_name:Faulty Fiber Channels on the Host, alarm_level:2.
[2017-03-08 15:24:02,543] [INFO ] [002587] [003489] [vbs_sysfs.c 2241] [BSB] report alarm, addinfo:FAIL_FIBER_CHANNEL=, alarm_type:1, alarm_id:15.1005005, alarm_name:Faulty Fiber Channels on the Host, alarm_level:2.
[2017-03-08 15:29:24,908] [INFO ] [002587] [003489] [vbs_sysfs.c 2241] [BSB] report alarm, addinfo:FAIL_FIBER_CHANNEL=, alarm_type:1, alarm_id:15.1005005, alarm_name:Faulty Fiber Channels on the Host, alarm_level:2.
[2017-03-08 15:35:02,874] [INFO ] [002587] [003489] [vbs_sysfs.c 2241] [BSB] report alarm, addinfo:FAIL_FIBER_CHANNEL=, alarm_type:1, alarm_id:15.1005005, alarm_name:Faulty Fiber Channels on the Host, alarm_level:2.
[2017-03-08 15:40:25,775] [INFO ] [002587] [003489] [vbs_sysfs.c 2241] [BSB] report alarm, addinfo:FAIL_FIBER_CHANNEL=, alarm_type:1, alarm_id:15.1005005, alarm_name:Faulty Fiber Channels on the Host, alarm_level:2.
2、让客户更换光纤线后再重新添加数据存储问题解决