s5700 给下挂ip话机poe供电,接口不停产生PD powered on/powered off日志

发布时间:  2017-03-18 浏览次数:  226 下载次数:  0
问题描述
s5700 给下挂ip话机poe供电,接口不停产生PD powered on/powered off日志,虽然不影响话机供电,但是已经完全影响配置管理交换机。
告警信息

告警日志如下:

Feb 28 2017 14:35:50 Quidway POE/4/POWERON:OID 1.3.6.1.4.1.2011.5.25.195.40.3 PD powered on.(IfIndex=31, Interface="GigabitEthernet0/0/27")
[Quidway]
Feb 28 2017 14:35:50 Quidway POE/4/POWEROFF:OID 1.3.6.1.4.1.2011.5.25.195.40.2 PD powered off.(IfIndex=12, Interface="GigabitEthernet0/0/8")
[Quidway]
Feb 28 2017 14:35:50 Quidway POE/4/POWERON:OID 1.3.6.1.4.1.2011.5.25.195.40.3 PD powered on.(IfIndex=39, Interface="GigabitEthernet0/0/35")
[Quidway]
Feb 28 2017 14:35:50 Quidway POE/4/POWEROFF:OID 1.3.6.1.4.1.2011.5.25.195.40.2 PD powered off.(IfIndex=31, Interface="GigabitEthernet0/0/27")

处理过程

1、确认poe电源功率是否足够,查看可用功率还有很多。

[Quidway]display poe information
PSE Information of slot 0:
    User Set Max Power(mW)     : 800000
    POE Power Supply(mW)       : 369600
    Available Total Power(mW)  : 316760
    Total Power Consumption(mW): 44840
    Power Peak Value(mW)       : 52579
    Power-Management Mode      : auto
    Power High Inrush          : disable


2、确认是否是线缆问题导致poe供电不稳定,更换线缆还是一样的报日志。


3、是否是用的表标准供电协议的ip话机,确认是华为的espace型号的ip话机。


4、最后对比不报日志和报日志的话机的供电区别,发现是报日志的话机还接了适配器在供电。

根因
话机的适配器和交换机poe同时供电,话机不停的切换供电设备导致不停产生PD powered on/powered off日志。
解决方案
把ip话机的适配器供电拔掉,PD powered on/powered off日志不再产生。
建议与总结
建议不要把poe供电设备的适配器和poe同时供电。

END