NE20E-S 业务单板亮红灯

发布时间:  2017-04-26 浏览次数:  197 下载次数:  0
问题描述
NE20E-S  业务单板亮红灯
告警信息


处理过程

命令查看单板状态均正常

display device
===============================================================================

NE20E-S4's Device status:
-------------------------------------------------------------------------------
Slot #   Type    Online     Register     Status     Role   LsId   Primary     
-------------------------------------------------------------------------------
1        PIC     Present    Registered   Normal     OTHER  0      NA          
5        NSP     Present    Registered   Normal     LC     0      NA          
6        MPU     Present    Registered   Normal     MMB    0      Master      
7        MPU     Present    Registered   Normal     MMB    0      Slave       
8        PWR     Present    Registered   Normal     OTHER  0      NA          
9        PWR     Present    Registered   Normal     OTHER  0      NA          
10       FAN     Present    Registered   Normal     OTHER  0      NA          
11       CLK     Present    Registered   Normal     OTHER  0      Master      
12       CLK     Present    Registered   Normal     OTHER  0      Slave       
-------------------------------------------------------------------------------


===============================================================================
                 display device pic-status
===============================================================================

Pic-status information :
--------------------------------------------------------------------------------
Pic#   Status       Type                      Port_count Init_result  Logic_down
--------------------------------------------------------------------------------
5/1    Registered   ETH_8xGFC_CARD            8          SUCCESS      SUCCESS  


2、clear alarm 清空告警后,单板告警灯还是亮红灯

3、查看告警信息

GigabitEthernet0/1/2端口接收光功率过低导致的告警


===============================================================================
                 display alarm history verbose
===============================================================================

Sequence    : 34       
AlarmId     : 0x8130055             AlarmName : hwEntityInvalid                                                
AlarmType   : equipment             Severity  : Critical         State : cleared
VS          : Admin-VS                       
StartTime   : 2017-04-20 16:24:46                    
Description : Physical entity failed. (BaseTrapSeverity=4, BaseTrapProbableCause=67697, BaseTrapEventType=5, EntityPhysicalIndex=16847107, EntPhysicalContainedIn=16842754, EntPhysicalName=GigabitEthernet0/1/2, RelativeResource=Optical Module, ReasonDescription=GigabitEthernet0/1/2 is failed, the optical module receive power is too low)
ClearTime   : 2017-04-21 09:54:56                    
ClearType   : service_resume     
ClearReason : A faulty physical entity recovered, and the fault caused by the faulty part was rectified. (BaseTrapSeverity=4, BaseTrapProbableCause=67697, BaseTrapEventType=5, EntityPhysicalIndex=16847107, EntPhysicalContainedIn=16842754, EntPhysicalName=GigabitEthernet0/1/2, RelativeResource=Optical Module, ReasonDescription=GigabitEthernet0/1/2 is failed, the optical module receive power is too low)

 

由于没有业务,收光过低告警接口shutdown后,单板告警灯消失

根因

接口收光过低,导致此单板stat 灯亮红灯。

解决方案


shutdown 此接口临时规避

最终解决方案是排除线路或模块导致光功率低问题

END