NE40E MPU10没有插好导致serdes打印告警

发布时间:  2012-12-31 浏览次数:  91 下载次数:  0
问题描述
版本信息:V600R003C05SPC300
故障现象:设备打印大量SFU13和LPU板之间serdes接口通信失败告警

 Alert            12-12-24  12:47:23      LPU1 is failed, SERDES No.1 channel No.1 with SFU13 SERDES No.9 channel
                                                              No.3 interface is lost synchronization

Emergency  12-12-24  12:47:26    Between SFU13 and LPU4, the communication channel of SERDES interface
                                                              input chip0 channel10 Peer SERDES¡¡chip0 channel0 is failed

 Emergency  12-12-24  12:47:26    Between SFU13 and LPU1, the communicat ion channel of SERDES 
                                                              interface input chip0 channel2 Peer SERDES¡¡chip0 channel0 is failed

 Emergency  12-12-24  12:47:21     SlotID10 is inserted, but some of the connecters are not detected
                                                               [BasCode:0x10200,EntCode:0x23000]

处理过程

NA

根因

10槽位主控板没有插紧导致

解决方案
MPU10当前为备用,请重新拔插MPU10单板;
建议与总结

单板插入设备,要检查是否有新增告警,避免后续再次进站进行恢复操作

END