FAQ-在NE40E NE80E如何透过命令确认与对端POS接口的J0,J1,C2叁数一致

发布时间:  2007-05-09 浏览次数:  87 下载次数:  2
问题描述
Q:
在NE40E/NE80E,如何透过命令确认与对端POS接口的J0,J1,C2叁数一致。


处理过程

根因
N/A
解决方案
A:
透过命令display pos inter pos <接口号>,在输出中的SDH OverHead可以看到传送及接收的J0,J1,C2叁数,如下:
SDH OverHead:
    Received PSL(C2): 0xcf, Transmitted PSL(C2): 0xcf
    Received section trace(J0):"0000000000000000000000000000000000000000000000000000000000000000"
    30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  
    Received path trace(J1):"gw2.tpe3 so-0/2/2"
    67  77  32  2e  74  70  65  33  20  73  6f  2d  30  2f  32  2f  32  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  d  a  
    Transmitted section trace(J0):"0000000000000000000000000000000000000000000000000000000000000000"
    30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  30  
    Transmitted path trace(J1):"gw2.tpe3 so-0/2/2"
    67  77  32  2e  74  70  65  33  20  73  6f  2d  30  2f  32  2f  32  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  d  a  
建议与总结

END