问题描述
某局点进行网络边界路由器替换,NE40E-X8(V6R1)需要与思科设备进行E1对接,链路调测中发现E1链路物理与协议均为down




处理过程
1、传输或链路问题
2、两端E1接口通道模式不一致
3、两端E1接口编码格式或帧格式不一致
4、两端E1接口协议层模式不一致
5、两端E1接口CRC不一致

根因

接口参数不一致

解决方案
1、检查链路与传输问题:
双方分别在DDF架上打远端硬环,接口物理均可以up,排除传输问题;
双方分别在接口上打远端软环(NE40E上为controller E1接口下loopback remote),双方接口物理均可up,排除链路问题;
2、检查双方E1接口均为通道化模式而非净通道模式,且所有时隙均绑定到一起
3、检查双方E1接口编码格式,均为HDB3(华为与思科均为默认)
4、检查双方帧格式,发现思科帧格式默认为CRC4,华为默认为no-CRC4
思科侧的接口状态:
E1 0/1/0 is down.
  Applique type is Channelized E1 - balanced
  Transmitter is sending remote alarm.
  Receiver has loss of frame.
  alarm-trigger is not set
  Version info Firmware: 20100222, FPGA: 13, spm_count = 0
  Framing is CRC4, Line Code is HDB3, Clock Source is Line.
  Data in current interval (15 seconds elapsed):
     0 Line Code Violations, 0 Path Code Violations
     0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 15 Unavail Secs
  Data in Interval 1:
     0 Line Code Violations, 18 Path Code Violations
     0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 900 Unavail Secs
更改华为接口帧格式为no-crc4,接口物理up,但协议仍然down
5、检查双方协议层格式,华为默认为PPP,思科默认为HDLC
更改华为接口格式为HDLC,仍然无法up,与思科协商,对端更改为PPP,协议仍然不能up
思科有自己独有的cisco-HDLC,与华为对接时建议使用PPP
6、双方均设置为PPP后,检查CRC,发现华为CRC默认32,思科默认16
更改华为CRC为16,协议层up

建议与总结
不同厂商接口对接,会涉及很多参数设置不一致导致的问题,需要逐一排查。附与思科E1对接成功后的配置(需要更改思科接口为PPP):
controller E1 1/1/0
channel-set 0 timeslot-list 1-31
description to-[Peoples]
undo shutdown
frame-format crc4
clock slave
#
interface Serial1/1/0:0
link-protocol ppp
crc 16
#

END