Patch file is error on slot 6 in MA5200

Publication Date:  2012-07-27 Views:  178 Downloads:  0
Issue Description
Equipment            : MA5300 (BRAS)
Software Version : MA5200V200R002B01D006
Patch                     :ma5200_23sph062.pat
Error                      :"Patch file is error on slot 6"
Slot 6                     : Master SMU 
While upgradation of Patch in MA5200 BRAS for BSNL NIB ,i got one  problem while loading the patch  got Error "Patch file is error on slot 6 " Slot 6 is  master SMU card .
Alarm Information
NULL
Handling Process
After getting the error massege .
1)i recheck the file name 
2) size of the patch file 
3)patch file was stored in the HD( hd directory)
4)I checked  "pwd "i was loading the file in flash directory 
5)Then i changed my directory cd hd:
6)Then again i gave command "patch load all ma5200_23sph062.pat"
it start  loading got massage " Patch load successed on master board then 
Patch load successed on slave board then subsequent SFU boards.
Root Cause
After the command "patch load all ma5200_23sph062.pat" got the error 
"Patch file is error on slot 6".
Suggestions
We need to be  aware on which directory  we are trying to load the patch file to avoid this Problem 

END