The NVR Controller Page Cannot Be Displayed Because the thttpd Process Is Abnormal

Publication Date:  2012-07-20 Views:  134 Downloads:  0
Issue Description
iNVS V100R002C02
After the URL of the NVR Controller is entered from a browser, the message The page cannot be displayed is displayed.
NVR Controller page display failure on Internet Explorer 6

Alarm Information
Handling Process
Run the /hinvs/psm/www/sbin/thttpd_wrapper & command to start the process.

Run the lsof -i:8188 command. If the thttpd process is started, the following output is displayed:

Normal thttpd process

Root Cause

Cause analysis:
1.         Connect an SSH tool to the NVR.
The default user name is root and default password is 123456.
2.         Run the lsof -i:8188 to listen to the port.
If the thttpd process is abnormal, the status of 8188 is not LISTEN in the output that is displayed.
Abnormal thttpd process