Wavelength division device switch mechanism problem caused that S9300 interface updown every other 5 minutes

Publication Date:  2012-11-08 Views:  144 Downloads:  0
Issue Description
Topology:
S9312-1-- Wavelength division 1---- Wavelength division 2--S9312-2
Phenomenon:
S9312-1  interface updown every other 5 minutes, the S9312-2 does not break.
Alarm Information
NULL
Handling Process
1. Make the loop for S9312-1 on wavelength division 1, it did not break in 20 minutes, it can exclude wavelength division 1, the link between wavelength division and S9300 interface failure possibility.
2. Make the loop for S9312-1 on wavelength division 2, it break, it can confirm that the failure caused by wavelength division failure.
3. S9300 interface updown every other 5 minutes, but it can confirm that S9312 has no mechanism that interface up and down every other 5 minutes, it can confirm that the failure caused by wavelength division failure.
The wavelength division engineer check the problem, find that configured the switching mechanism for every 5 minutes, change wavelength division side configuration, the failure recovered.
Root Cause
1. The link failure between S9312-1 and wavelength division.
2. S9312-1 interface failure
3. S9312-1 side wavelength division failure
4. Link between wavelength division or the wavelength division failure.
Suggestions
It is not the switch side problem when it appeared interface up and down for fixed time space, it is suggested to check the wavelength division side switching mechanism.