Screen will flash for 1m when power on the TP3006

Publication Date:  2013-07-29 Views:  158 Downloads:  0
Issue Description
when power on the TP3006. the middle and right screens will last flashing for 1minute.
Alarm Information
did not have
Handling Process
1.  check the power cable and image cable were seprated
2.  check the parameter of middle terminal was same with the other terminals
3.  check the parameter of Tri-lens camera , found that the resolution of camera was 720P, but the resolution of terminal was 1080P.
correct the parameter to match with each other.
Root Cause
1.  check the background that Engineer replace a new middle terminal.
2.  suspect the power cable was mixed with Image cable
3.  the configuration
Suggestions
flashing have many result. most reason was because that power cable and image cable were mixed.
but the different  resolution  can make flashing  too.