Easy-operation function does not work on S5700 switch

Publication Date:  2014-11-29 Views:  897 Downloads:  0
Issue Description
Customer bought our S5700 switch and wanted to implement easy operation functionHowever, customer found that function did not work correctly.
Alarm Information
<HUAWEI>
Nov 28 2014 23:11:12-05:13 HUAWEI %%01EZOP/3/PROCESS_STOP(l)[0]:Easy-operation upgrade process has been stopped. (Reason=There is a configuration file in this device)
<HUAWEI>
Handling Process
1. From the Alarm information, there is already one configuration existed in the device. Let customer "reset saved-configuration" and then "reboot" the swtich.
2. After that, still get above alarm logs on the device and easy-operation is stopped.
3. Make a local test and find that there must be not any "*.cfg" or "*zip" in Flash. Let customer delete all the configuration files in the device and then test it again. The problem is solved. 
Suggestions
There are two points need to be paid attention for easy-operation function:
1. Configuration file as above analysis.
2. Cannot use console during easy-operation process. Once any input from console, easy-operation will be stopped and get below alarm in logs
Nov 28 2014 23:43:38-05:13 HUAWEI %%01EZOP/3/PROCESS_STOP(l)[0]:Easy-operation upgrade process has been stopped. (Reason=Input has been detected in the console)

END