IP Address Failover Deployment Guide 10

OceanStor 5300 V3, 5500 V3, 5600 V3, 5800 V3, and 6800 V3 Storage System V300R003

"This document describes the working principle, planning, configuration, and management of IPaddress floating."
Rate and give feedback :
この文書の日本語を含む他言語への翻訳は、元の文書の内容の理解を支援する目的で提供されています。翻訳には機械翻訳が利用され、人間による簡単な校正のみが行われています。 注: 最先端の機械翻訳を利用した場合でも、翻訳の品質はプロの翻訳者による翻訳ほど十分ではありません。ファーウェイは、翻訳の正確性についていかなる責任も負わないものとします。リンクを使用して、英語版の元の文書も同時に参照することを推奨します。
About This Document

About This Document

Purpose

This document describes the IP Address Failover Deployment provided by OceanStor 5300 V3/5500 V3/5600 V3/5800 V3/6800 V3 storage system in terms of working principles, planning, configuration example, and management operations.

Intended Audience

This document is intended for:

  • Technical support engineers
  • Maintenance engineers

Symbol Conventions

The symbols that may be found in this document are defined as follows.

Symbol

Description

Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.

Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.

Indicates a potentially hazardous situation which, if not avoided, could result in equipment damage, data loss, performance deterioration, or unanticipated results.

NOTICE is used to address practices not related to personal injury.

Calls attention to important information, best practices and tips.

NOTE is used to address information not related to personal injury, equipment damage, and environment deterioration.

Change History

Changes between document issues are cumulative. The latest document issue contains all the changes in earlier issues.

Issue 10 (2018-12-10)

This issue is the tenth official release. The updates are as follows:

Optimized some descriptions.

Issue 09 (2018-05-30)

This issue is the ninth official release. The updates are as follows:

Optimized some descriptions.

Issue 08 (2017-11-30)

This issue is the eighth official release. The updates are as follows:

Optimized some description in section Creating a Bond Port.

Issue 07 (2017-10-30)

This issue is the seventh official release. The updates are as follows:

Optimized some description in section Bond Port-based Configuration Example.

Issue 06 (2017-05-10)

This issue is the sixth official release. The updates are as follows:

Updated networking and descriptions in sections Ethernet Port-based IP Address Failover and Bond Port-based IP Address Failover.

Issue 05 (2016-11-20)

This issue is the fifth official release.

  • Replaced float by fail over
  • Optimized some description in operation steps.

Issue 04 (2016-07-25)

This is the fourth official release.

  • Synchronizes some software interface changes.
  • Optimizes description of principle.

Issue 03 (2016-04-30)

This is the third official release.

Synchronizes some software interface changes.

Issue 02 (2015-12-10)

This is the second official release.

Synchronizes some software interface changes.

Issue 01 (2015-08-30)

This is the first official release.

ダウンロード
Updated: 2018-12-10

ドキュメント番号: EDOC1000084199

閲覧数:9451

ダウンロード: 406

Average rating:
This Document Applies to these Products