選択した言語が見つかりません。

このサイトはCookieを使用しています。 サイトを閲覧し続けることで、Cookieの使用に同意したものとみなされます。プライバシーポリシーを読む>

OceanStor 9000 V300R005C00 Planning Guide 07

Rate and give feedback :
この文書の日本語を含む他言語への翻訳は、元の文書の内容の理解を支援する目的で提供されています。翻訳には機械翻訳が利用され、人間による簡単な校正のみが行われています。 注: 最先端の機械翻訳を利用した場合でも、翻訳の品質はプロの翻訳者による翻訳ほど十分ではありません。ファーウェイは、翻訳の正確性についていかなる責任も負わないものとします。リンクを使用して、英語版の元の文書も同時に参照することを推奨します。
About This Document

About This Document

Intended Audience

This document is intended for:

  • Technical support engineers
  • Maintenance engineers

Symbol Conventions

The symbols that may be found in this document are defined as follows.

Symbol

Description

Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.

Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.

Indicates a potentially hazardous situation which, if not avoided, could result in equipment damage, data loss, performance deterioration, or unanticipated results.

NOTICE is used to address practices not related to personal injury.

Calls attention to important information, best practices and tips.

NOTE is used to address information not related to personal injury, equipment damage, and environment deterioration.

Change History

Issue 07 (2018-10-30)

This issue is the seventh official release.

Issue 06 (2018-05-30)

This issue is the sixth official release.

Issue 05 (2016-11-23)

This issue is the fifth official release.

10GE Network Deployment Solution->IP Address Planning for P12/P25/P36/C36 Nodes->IPv4 Networking Example

The planning number of management network IP address is modified.

Issue 04 (2016-09-15)

This issue is the fourth official release.

  • Overview

    Added notes that configurations of the customer service network must be better understood in advance to avoid adverse impact on the service network caused by OceanStor 9000 access.

  • IB Network Deployment Solution

    QSFP high-speed cables are replaced with FDR cables to be compatible with the SX6018 switches.

    Added note that the paired InfiniBand switches must be cascaded using ports 17 and 18 for to implement interconnection.

Issue 03 (2016-07-15)

This issue is the third official release.

IS5023 IB switches are deleted, and SX6018 IB switches are added.

Issue 02 (2016-04-15)

This issue is the second official release.

Issue 01 (2015-12-30)

This issue is the first official release.

ダウンロード
Updated: 2018-10-27

ドキュメント番号: EDOC1000095819

閲覧数:3243

ダウンロード: 58

Average rating:
This Document Applies to these Products
関連ドキュメント
Share
戻る 次へ