Configuration Guide - Interface Management

S1720, S2700, S5700, and S6720 V200R010C00

This document describes the principles and configurations of interfaces and provides configuration examples.
Rate and give feedback :
この文書の日本語を含む他言語への翻訳は、元の文書の内容の理解を支援する目的で提供されています。翻訳には機械翻訳が利用され、人間による簡単な校正のみが行われています。 注: 最先端の機械翻訳を利用した場合でも、翻訳の品質はプロの翻訳者による翻訳ほど十分ではありません。ファーウェイは、翻訳の正確性についていかなる責任も負わないものとします。リンクを使用して、英語版の元の文書も同時に参照することを推奨します。
About This Document

About This Document

Intended Audience

This document is intended for network engineers responsible for switch configuration and management. You should be familiar with basic Ethernet knowledge and have extensive experience in network deployment and management.

Symbol Conventions

The symbols that may be found in this document are defined as follows.

Symbol

Description

Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.

Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.

Indicates a potentially hazardous situation which, if not avoided, could result in equipment damage, data loss, performance deterioration, or unanticipated results.

NOTICE is used to address practices not related to personal injury.

Calls attention to important information, best practices and tips.

NOTE is used to address information not related to personal injury, equipment damage, and environment deterioration.

Command Conventions

The command conventions that may be found in this document are defined as follows.

Convention

Description

Boldface

The keywords of a command line are in boldface.

Italic

Command arguments are in italics.

[ ]

Items (keywords or arguments) in brackets [ ] are optional.

{ x | y | ... }

Optional items are grouped in braces and separated by vertical bars. One item is selected.

[ x | y | ... ]

Optional items are grouped in brackets and separated by vertical bars. One item is selected or no item is selected.

{ x | y | ... }*

Optional items are grouped in braces and separated by vertical bars. A minimum of one item or a maximum of all items can be selected.

[ x | y | ... ]*

Optional items are grouped in brackets and separated by vertical bars. Several items or no item can be selected.

&<1-n>

The parameter before the & sign can be repeated 1 to n times.

#

A line starting with the # sign is comments.

Interface Numbering Conventions

Interface numbers used in this manual are examples. In device configuration, use the existing interface numbers on devices.

Disclaimer

This document is designed as a reference for you to configure your devices. Its contents, including web pages, command line input and output, are based on laboratory conditions. It provides instructions for general scenarios, but does not cover all use cases of all product models. The examples given may differ from your use case due to differences in software versions, models, and configuration files. When configuring your device, alter the configuration depending on your use case.

The specifications provided in this document are tested in lab environment (for example, the tested device has been installed with a certain type of boards or only one protocol is run on the device). Results may differ from the listed specifications when you attempt to obtain the maximum values with multiple functions enabled on the device.

Product Software Versions Matching NMS Versions

The product software versions matching NMS versions are as follows.

S1720, S2700, S5700, and S6720 Product Software Version

eSight

V200R010C00

V300R007C00 (not matching the S1720)