It cann't get online as MA5200F VLAN relay-leased-line user authenticate locally

Publication Date:  2012-07-27 Views:  66 Downloads:  0
Issue Description

As MA5200F VLAN relay-leased-line user authenticate locally, it cann't get online.


Alarm Information
No

Handling Process

1、Check the dedicated status of vlan is Updating
2、Check the data configuration and detect the configuration is the local authentication,and detect the configuration is the local authentication,the authentication mode in the account is B show as following:
display user                                                   
  ---------------------------------------------------------------------------- 
  No.  User-Name   State  PortMask CAR  Access-Limit Online 
  ---------------------------------------------------------------------------- 
  0    user@relay        A      B        2    1                 0 
3、The problem located as the authentication mode in the account is B,the system will consider this VLAN is service VLAN,the existed service VLAN does not allow to make VLAN relay service.
4、Amend the authentication mode in the account to A and then reconfigure PORTVLAN to transfer the dedicated line, the service is normal.


Root Cause

The reasons is data configuration.
Summary: As MA5200F VLAN relay-leased-line user authenticate locally, the authentication mode in the account must be A (it is the default value).


END