R1760 connects to S8016 via Ethernet port directly, and 50% of packets are discarded in mutual ping.

Publication Date:  2012-07-27 Views:  95 Downloads:  0
Issue Description
R1760 connects to S8016 via Ethernet port directly, and 50% of packets are discarded in mutual ping.

Alarm Information
No

Handling Process
Check the route table. It is found that the user is configured with two default routes, of which one points to S8016, and the other to another else equipment in internal network, resulting in 50% packets discarded. The problem is solved by deleting the default route to internal network.  

Root Cause
No

END