No Echo for AR28-30 Inverse TELNET

Publication Date:  2012-07-27 Views:  148 Downloads:  0
Issue Description
AR28-30 serves as Server, with version as VRP3.4-0006; AR18-33 as Client, being atVRP3.3-0013. 
The configuration of TTY corresponded by AR28-30 is as follows: 
user-interface tty 17                                                          
undo shell                                                            
redirect enable                                                               
redirect return-deal from-telnet                                               
redirect listen-port 5000
TELNET to AR18-33 inversely, although with successful connection, there is no echo from cliet. 
Alarm Information
No
Handling Process
Under user-interface tty 17, configure the flow-control none command, and inverse TELNET is normal. 
Root Cause
For inverse interconnection between TELNET Server and Client, it needs to cancel flow-control sometimes. By default, the equipment enables hardware flow-control at TTY.
Suggestions
Inverse TELNET has multiple options in configuration, and some is related to hardware system.  If problem occurs,  please try to modify the options for configuration.

END