NE40E cannot link with NE40 using serial interfaces (E1).

Publication Date:  2012-07-27 Views:  199 Downloads:  0
Issue Description
create MP-group between NE40E-X3 and NE40-8.
NE40E-X3 version is V600R001C00SPC800.
NE40-8 version is V300R005C01B322.
cPOS controller is used to connect to SDH equipment. Several E1 serial interfaces make MP-groups.
After standart configuration of MP-group the Line protocol of MP-group should become UP, but the status is Down.
#
interface Serial1/1/0/1:0
 link-protocol ppp
 ppp mp Mp-group 1/1/26
#
interface Mp-group1/1/26                  
 ip address x.x.x.x 255.255.255.252
 isis enable 5
 isis circuit-level level-2
 isis authentication-mode md5 Z9;<F6T]SKXS`X=Na7I'"1!!
 isis cost 20000 level-2
 mpls
 mpls ldp
 trust upstream default
#
Alarm Information
Line protocol of the MP-group remain DOWN.
Handling Process
Configure crc16 mode at member Serial interfaces of NE40E-X3.
using command "crc 16" in serial interface view.
#
interface Serial1/1/0/1:0
 link-protocol ppp
 ppp mp Mp-group 1/1/26
 crc 16
#
Root Cause
The crc parameter of Serial interfaces on peer devices should be the same. 
NE40E-X3 can support two modes : crc16 and crc32. By default crc32 is used. 
But NE40-8 only support crc16 mode.
Suggestions
 