An ECC Error Occurs on the DRAM of a RAID Card Because the RAID Card Is Faulty

Publication Date:  2012-07-17 Views:  167 Downloads:  0
Issue Description
Related information about the product and version: CSS V100R001C01 Database Volume.
During the RAID group initialization, the 0xB02160006 A serious error occurs on the DRAM of the RAID card alarm is reported to the ISM. As a result, the RAID group initialization fails.
 
Alarm Information
None
Handling Process
Step 1     Replace the RAID card.

                               Step 2     Switch on the power supply, and start the device.

After the RAID card is replaced, the RAID card automatically identifies the information about the RAID group. Therefore, you do not need to add hard disks manually.

                               Step 3     After the device is started, check whether the 0xB02160006 A serious error occurs on the DRAM of the RAID card alarm disappears from the ISM interface.

l   If yes, the fault is removed.

l   If no, contact technical support engineers.

----End

Root Cause
On the ISM interface, the alarm listed in Table 1-9 is reported.
Table 1-1 Alarm of the ECC error on the DRAM of a RAID card
Alarm ID Alarm Name Alarm Cause Alarm Description
0xB02160006 A serious error occurs on the DRAM of the RAID card An error occurs on the DRAM of the RAID card on the device. A multi-bit ECC error occurs on the DRAM of the RAID card on the device ([dev-name]); location: cloud storage domain ([domain-name]), rack ID ([rack]), frame ID ([frame])

According to the alarm information, the ECC error occurs because the RAID card memory is faulty. The root cause is that the RAID card is faulty.
 
 