How to Load a Battery Module During the Oceanspace S2300 Power-on Process

Publication Date:  2012-07-22 Views:  447 Downloads:  0
Issue Description
During the power-on process of the Oceanspace S2300, a battery module is loaded successfully, but the other fails. 
Alarm Information
None
Handling Process
Step 1  Replace the power module without the battery management function with one having the function. The fault is rectified.
Step 2  When you apply for spare parts, check the BOM information of the bar code (first six digits) of a power module, and then check whether the power module has the battery management function on the deployment site. (Only the power module has the battery management function can be used together with the battery module.)
Root Cause
The BOM information on the bar codes of the two power modules of the S2300 indicate that they are of different types, that is, one power module has the battery management function while the other does not; therefore, one battery module fails to be loaded. 
Suggestions
It is recommended to install the power modules of the same type; otherwise, the power modules are incompatible, and the controller enclosure fails to be powered on.

END