Upgrade Failure Occurs When the /cf_data/image Directory Is Accessed During Upgrade

Publication Date:  2012-07-22 Views:  130 Downloads:  0
Issue Description

When the storage device is upgraded in a project, controller A prompts cf_data/image is busy, causing the upgrade to fail.

Product and version information:
  • S5000 series
Alarm Information
None
Handling Process
CAUTION:

This operation would interrupt the services, please operate with caution and back up data in advance.

Upgrade controller B after controller A is removed manually. When the upgrade completes, reinsert controller A to upgrade it automatically to the version of controller B.

Root Cause
  1. It is found that all the logon windows have exited the /cf_data directory and its subdirectories.
  2. When the command fuser -vm /cf_data/image is executed to check whether a process is accessing the directory, it is found that the cf_data/image is busy as it is being accessed during the upgrade, causing the upgrade to fail.
Suggestions

Make sure the cf_data/image directory is not being accessed during the upgrade. If it is being accessed, please exit it normally and then continue to upgrade.