The Method to Judge The Version Number of the Loaded Software When USG2200 Cannot Enterthe System

Publication Date:  2012-09-12 Views:  161 Downloads:  0
Issue Description
It needs to determine the software packet that is corresponding to the upgraded version of the corresponding firewall when USG2200 cannot enter the system normally to upgrade software version
The next is to introduce the method to judge the version of the loaded software when device cannot start to login
Alarm Information
Null
Handling Process
1、 restart the device, pay attention to the following message when it occurs the double line of *
V100R002 Version
Begin with 02 in big bootroom, it means the current version is V100R002
*********************************
*********************************
Small Bootrom Ver : 020 Dec 17 2009
Big Bootrom Ver : 028 Dec 17 2009
Logical Ver : 010
PCB Ver : VER.B
CPU Frequency : 750 MHz
CPU Type : XLS208 Rev1

V100R003 Version
Begin with 03 in big bootroom, it means the current version is V100R003
Small Bootrom Ver : 302 Jun 26 2010
Big Bootrom Ver : 337 May 24 2010
Logic Ver : 007B
PCB Ver : VER.A
CPU Frequency : 750 MHz
CPU Type : XLS208 Rev1

V100R005 Version
Begin with 05 in big bootroom, it means the current version is V100R005
Small Bootrom Ver : 517 Dec 30 2010
Big Bootrom Ver : 578 Oct 21 2011
Logical Ver : 004B
PCB Ver : VER.A
CPU Frequency : 750 MHz
CPU Type : XLS208 Rev1

notice:it is acceptable that the version number of the small bootroom and big bootroom is inconsistent, the VRP software version is consistent with big bootroom

Root Cause
Null
Suggestions
Null

END