Configuration for the Two-node cluster hot backup lost

Publication Date:  2012-09-13 Views:  76 Downloads:  0
Issue Description
Two USG5330 to do the Two-node cluster hot backup, when the electricity cut down and the equipments restart, one of the USG5330 loss a part of configuration, result in the different configuration of two USG5330, some operations can’t run normally.
Alarm Information
none
Handling Process
Import the configuration from the USG5330 which has the whole configuration to the USG5330 which loss the configuration by batch manually. 
Root Cause
The USG5330 which loss the configuration didn’t save the configuration before the cut down of electricity.
Suggestions

When we change the configuration at one USG5330, and synchronized at another USG5330, we should save the configuration at the second USG5330.

END