S9300 version V100R002C00SPC200 cannot add the SPH006 mend

Publication Date:  2012-10-30 Views:  573 Downloads:  0
Issue Description
S9300 version V100R002C00SPC200, it cannot add the SPH006 hot mend.
Alarm Information
<S9306-01>patch load cfcard:/s9300v100r002sph006.pat all
Info: The patch is being loaded. Please wait for a moment.
Info: The slot 1 does not have C patch to be loaded.
Info: The slot 2 does not have C patch to be loaded.
Info: The master board does not have C patch to be loaded.
Info: The slave board does not have C patch to be loaded.
Info: Finished loading the patch.

Handling Process
Deploy the site using S9300V100R002C00SPC200 version.
Confirm which basic version the mend correspond by view the mend introduction before adding the mend.
Root Cause
S9300 V1R2 SPH006 mend basic version are the following version:
S9300V100R002C00SPC001
S9300V100R002C00SPC002
S9300V100R002C00SPC100
Device version is S9300V100R002C00SPC200,which is newest version of 9300,there is not mend at present,SPH006 cannot be added on this version.
Suggestions
NULL

END