MiniMCU terminal can't link toTE30

Publication Date:  2013-08-31 Views:  211 Downloads:  0
Issue Description
Use RP100 with 9039S-M to hold a meeting,video flow single-pass,there are three sites in this meeting
the other two is  RP200 and TE30
The version of 9039s-m is V100R010B057SP04
When use point to point mode ,everything is ok,but in multipoint meeting ,video flow single-pass.
Alarm Information

Can't receive streams from other side
Handling Process
upgrade the terminal to last version and problem resolved
Root Cause
the software version of 9039s-m is too low,may not matched with TE30
Suggestions
the version of all equipments in one system should be matched

END